Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: SCIENTIFIC GLASS OF FLORIDA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCIENTIFIC GLASS OF FLORIDA, INC. in 201 NORTHSTAR CT, SANFORD, FL 32771 (NAICS 327212). OSHA activity number 339780785.

Watch Scientific Glass OF Florida, INC. — free Get an email when a new federal OSHA severe-injury report for Scientific Glass OF Florida, INC. is published. One employer, no account, unsubscribe in one click.
Site address
201 NORTHSTAR CT
City
SANFORD
State
FL
ZIP
32771
Mailing
201 NORTHSTAR CT, SANFORD, FL 32771
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327212
Employees
25
Ownership type
A

19 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1764.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by fragments of plastic pipe used to transport compressed air for the operation of air operated tools and air used for cleaning, in the event the piping ruptures:     a. Throughout the facility, polyvinyl chloride ( PVC ) plastic pipe was used to transport compressed air in exposed above ground locations, for the use of air operated tools and air used for cleaning, a practice not recommended by the Plastics Pipe Institute and prohibited by ANSI/ASME B31.8-1986, Gas Transmission and Distribution Piping Systems standard.
Recent events (2)
  • — I (S) $1764
  • — Z (S) $2800

1910.103 B01 III A

Serious Gravity 10 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1764.00 Reduced
29 CFR 1910.103(b)(1)(iii)(a): Piping, tubing, and fittings were not suitable for hydrogen service and for the pressures and temperatures involved:    a. Lathe resize area, at lathes such as, but not limited to, lathe number 10, lathe number 9, lathe number 8 and lathe number 3,  employees were exposed to a fire hazard, in that, hydrogen gas supply to the lathes was made by using rubber type hoses under or adjacent to the lathes without being protected from high heat.
Recent events (2)
  • — I (S) $1764
  • — Z (S) $2800

1910.147 C04 I

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1764.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     a. Employees were exposed to struck by hazards during maintenance work, in that, procedures were not developed and implemented to address inadvertent activation of the equipment or release of stored energy while maintaining equipment such as, but not limited to, lathes, ovens, a milling machine, and saws.
Recent events (2)
  • — I (S) $1764
  • — Z (S) $2800

1910.151 C

Serious Gravity 5 2 instances 20 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1260.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a. Dip tank and rinse area, employees were exposed to a chemical hazard, in that, an eyewash station and body wash shower were not provided in the area where ammonium bifluoride solution was used during etching.    b. Forklift charge area, employees were exposed to a chemical hazard, in that, an eyewash station and body wash shower were not provided in the area where the forklift battery was charged and maintained.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2000

1910.212 A01

Serious Gravity 10 3 instances 20 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1764.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     a. Throughout the manufacturing area, employees were exposed to a struck-by hazard, in that, 20 lathes equipped with a three jaw chuck on both ends were not provided with a guard over the rotating chuck.    b. Cutting and cleaning area, employees were exposed to a struck by hazard, in that, a guard was not provided at the tension wheel for the sanding belt of the Summer Maca sander.    c. Maintenance room, employees were exposed to a struck-by hazard, in that, a guard was not provided at the non-cutting portion of the blade of the Delta band saw.
Recent events (2)
  • — I (S) $1764
  • — Z (S) $2800

1910.212 A03 II

Serious Gravity 10 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1764.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a. M & B Department, employees were exposed to a struck by hazard, in that a guard was not provided on the Victor Milling machine to protect employees form the rotating chuck bid holder.
Recent events (2)
  • — I (S) $1764
  • — Z (S) $2800

1910.212 B

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $756.00 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a. Cutting and cleaning area, employees were exposed to a struck by hazard, in that, a Rockwell pedestal drill press machine number 38 was not secured in place as designed.
Recent events (2)
  • — I (S) $756
  • — Z (S) $1200

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1020.00 · Current $643.00 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    a. Maintenance room, employees were exposed to a struck-by hazard, in that, a tongue guard was not provided at the right side grinding wheel of a Ryobi bench grinder.
Recent events (2)
  • — I (S) $642.6
  • — Z (S) $1020

1910.219 C02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $756.00 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:     a. Cutting and cleaning area, employees were exposed to a caught-by hazard, in that, the rotating shaft for the motor of the Pistorius saw machine number 42 did not have a guard over the rotating parts.
Recent events (2)
  • — I (S) $756
  • — Z (S) $1200

1910.219 D01

Serious Gravity 1 3 instances 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a. Lathe resize area, employees were exposed to a caught-by hazard, in that, the rotating pulley of the vacuum pump for lathe number 9 was not guarded.  b. Cutting and cleaning area, employees were exposed to a caught-by hazard, in that, the rotating pulley of the Pistorius saw machine number 42 did not have a guard that would fully enclose the moving parts.  c. Cutting and cleaning area, employees were exposed to a caught-by hazard, in that, the two rotating pulleys on top of the Rockwell drill press, machine number 38, did not have a guard that would fully enclose the moving parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E01 I

Serious Gravity 1 2 instances 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):  a. Lathe resize area, employees were exposed to a caught-by hazard, in that, the rotating belt of the vacuum pump for lathe number 9 was not guarded.  b. Cutting and cleaning area, employees were exposed to a caught-by hazard, in that, the rotating belt on top of the Rockwell drill press, machine number 38, did not have a guard that would fully enclose the moving parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E03 I

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)  a. Cutting and cleaning area, employees were exposed to a caught-by hazard, in that, the moving belt of the Pistorius saw machine number 42 did not have a guard that would fully enclose the moving parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $756.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    b. M & B Department, employees were exposed to a struck by hazard, in that, an air nozzle was used for cleaning at a 90 p.s.i. pressure.
Recent events (2)
  • — I (S) $756
  • — Z (S) $1200

1910.305 B01 I

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1008.00 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:    a. Oven number 19, employees were exposed to an electrical hazard, in that, a flexible cord used to provide power to a foot operated switch was passed through a vent at the side of the oven control cabinet without abrasion protection.
Recent events (2)
  • — I (S) $1008
  • — Z (S) $1600

1910.305 B01 II

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a. Bench department, employees were a exposed to an electrical hazard, in that, the disconnect box for lathe number 66 was missing a knockout.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 4 instances 20 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $756.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a. Laser room, employees were exposed to an electrical hazard, in that, a red extension cord was used to provide power to the laser cutting table light.    b. Laser room, employees were exposed to an electrical hazard, in that, a red extension cord was used to provide power to the laser's aiming light.    d. M & B Department, employees were exposed to an electrical hazard, in that, a red extension cord was used to provide power to the equipment near the milling machine.
Recent events (2)
  • — I (S) $756
  • — Z (S) $1200

1910.305 G02 III

Serious Gravity 1 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a. Lathe number 4 area, employees were expose to electrical hazards, in that, a red extension cord used to provide power to floor fans had the outer sheath of the insulation pulled from the plug.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 J02 IV

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1008.00 Reduced
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:    a. Cutting and cleaning area near the lapping surface grinding machine, employees were exposed to an electrical hazard, in that, a general type 4-way outlet box without a cover was  installed on the wall near the machine and was subject to getting wet.
Recent events (2)
  • — I (S) $1008
  • — Z (S) $1600

1910.306 J05

Deleted Serious Gravity 1 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1910.306(j)(5): Electric equipment operating at more than 15 volts, including power supply cords, used with fountains was not protected by ground-fault circuit interrupters:   a. Manufacturing area, employees were exposed to an electrical hazard, in that, the water drinking fountain was not plugged into a GFCI  protected outlet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339780785.