VERNON, CT ·
OSHA Inspection: SOLDREAM, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SOLDREAM, INC. in 129 RESERVOIR ROAD, VERNON, CT 06066 (NAICS 336412). OSHA activity number 339780868.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOLDREAM, INC.
- Site address
- 129 RESERVOIR ROAD
- City
- VERNON
- State
- CT
- ZIP
- 06066
- Mailing
- 129 RESERVOIR ROAD, VERNON, CT 06066
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336412
- Employees
- 65
- Ownership type
- A
Citations
16 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 31, 2014
- Abate by
- Jan 30, 2015
- Penalty
- Initial $3,850 · Current $2,503 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards where combustible metal dust was generated: A. De-burring Room: On, or about, May 19, 2014, an Easy Bench down draft work bench caught on fire while an employee was de-burring titanium aircraft parts. The two Airflow Systems, Inc. down draft workbenches, Model Easy Bench ALUM-BF1-MAT, had not been designed or equipped for use with titanium and lacked adequate controls to protect employees from fires and/or explosion hazards that could result from the improper use of the work benches. B. De-burring Room: On, or about May 23, 2014, a dust collection system that consisted of ductwork and a Donaldson Torit Model 24 cyclone dust collector that was used to collect titanium, Inconel, stainless steel and abrasive blasting dusts, had not been designed, installed, or maintained to protect employees against fire and explosion hazards.
Recent events (2)
- · I (S) $2502.5
- · Z (S) $3850
1910.107 B05 I
- Issued
- Oct 31, 2014
- Penalty
- Initial $3,850 · Current $2,503 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarms or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained: Paint Room: On, or about, May 27, 2014, the spray booth used when MolyKote D-321, a Category 3 flammable liquid, was applied to parts, was not provided with a manometer.
Recent events (2)
- · I (S) $2502.5
- · Z (S) $3850
1910.107 B05 IV
- Issued
- Oct 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: Paint Room: On, or about, May 27, 2014, the spray booth used when MolyKote D-321, a Category 3 flammable liquid, was applied to parts, was not provided with sprinkler protection both upstream and downstream of the filters.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.107 G03
- Issued
- Oct 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(3): Approved metal waste cans were not provided wherever rags or waste were impregnated with finishing material; and all such rags or waste were not deposited therein immediately after use. The contents of waste cans were not properly disposed of at least once daily or at the end of each shift: Paint Room: On, or about, May 27, 2014, a plastic, uncovered waste can that contained used cans of MolyKote D-321, a Category 3 flammable liquid, and rags used in the coating process was left in the spray booth.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.107 C09 I
- Issued
- Oct 31, 2014
- Penalty
- Initial $3,850 · Current $2,503 Reduced
General-duty citation text
29 CFR 1910.107(c)(9)(i): 29 CFR 1910.107(c)(9)(i): All metal parts of piping systems conveying flammable or combustible liquids were not properly electrically grounded in an effective and permanent manner: Paint Room: On, or about, May 27, 2014, the Paasche spray pen used to apply MolyKote D-321, a Category 3 flammable liquid, was not grounded during use. The hose provided with the gun was rubber with a cloth covering.
Recent events (2)
- · I (S) $2502.5
- · Z (S) $3850
1910.157 G03
- Issued
- Oct 31, 2014
- Penalty
- Initial $3,080 · Current $2,002 Reduced
General-duty citation text
29 CFR 1910.157(g)(3): Employees who have been designated to use fire fighting equipment as part of the emergency action plan were not provided training in the use of the appropriate equipment: Plant: On, or about, May 30, 2014, the company had not provided hands-on training regarding the use of portable fire extinguishers to employees who would be expected to response in the event of an incipient stage fire.
Recent events (2)
- · I (S) $2002
- · Z (S) $3080
1910.178 A05
- Issued
- Oct 31, 2014
- Abate by
- Jan 30, 2015
- Penalty
- Initial $2,310 · Current $1,502 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered. Plates, tags or decals were not changed: Warehouse: On, or about, May 27, 2014, the Crown forktruck, serial number 96131, was not provided with a revised tag or plate to indicate the reduced capacity of the forktruck when the barrel lifting attachment was used.
Recent events (2)
- · I (S) $1501.5
- · Z (S) $2310
1910.212 A01
- Issued
- Oct 31, 2014
- Abate by
- Jan 30, 2015
- Penalty
- Initial $5,390 · Current $3,504 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Plant: On, or about, May 27, 2014, the following machining centers were not provided with adequate safeguarding: A. Milling Department: The following CNC machines were found to have access doors that could be opened during the automatic mode when the tooling was in operation: 1. Machine #31, Hyandai-Kia horizontal milling, Model KH636: The access door interlock was bypassed, the key had been removed from the door and inserted into the receiver. 2. Machine #4 Fadal, Model VMC4020 milling center: Half of the access door interlock mechanism was missing and had been removed from the machine. 3. Machine #1 Fadal, Model VMC4020 milling center: The access door was not provided with an interlock. 4. Machine #2 Fadal, Model VMC4020 milling center: The access door was not provided with an interlock. 5. Machine #21 Fadal: The access door interlock had been bypassed. 6. Machine #18 Fadal: The access door had a binder clip secured to the interlock to bypass it. 7. Machine #5 Fadal:. The access door interlock was bypassed and secured with duct tape. 8. Machine #12 Fadal: The access door interlock was bypassed and secured with duct tape. 9. Machine #17 Fadal VMC 4020: The access doors to the machining area of the machine were not provided with interlocks and could be opened during the automatic mode. 10. Machine #30 Fadal VMC 4020: The access doors to the machining area of the machine were not provided with interlocks and could be opened during the automatic mode. 11. Machine #14, #13, #16 and #15, identical Compumill HMC-410 milling centers: None of the access doors were provided with interlocks. B. Turning Department: On, or about, May 27, 2014, the window provided in the access door of Machine #27, a Clausing/Colchester turning center, was shattered due to tool breakage. The window had not been replaced after the incident and it was unlikely that the window could withstand another similar impact and remain intact.
Recent events (2)
- · I (S) $3503.5
- · Z (S) $5390
1910.242 B
- Issued
- Oct 31, 2014
- Penalty
- Initial $3,080 · Current $2,002 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Warehouse Machining Area: On, or about, May 27, 2014, air nozzles used to clean chips off parts were measured to be greater than 30 p.s.i., dead-ended: A. Kuraki KBM-11X horizontal boring machine. B. Hyundai-Kia Model KH636 milling center.
Recent events (2)
- · I (S) $2002
- · Z (S) $3080
1910.303 B02
- Issued
- Oct 31, 2014
- Abate by
- Jan 30, 2015
- Penalty
- Initial $3,850 · Current $2,503 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: De-burring Department: On, or about, May 23, 2014, combustible metal dust had accumulated on the following electrical equipment: A. Easy Bench Model ALUM-BF1-MAT down draft table, serial number 1027948: The fan unit and its electrical wiring, including a switch connection, had titanium dust coated onto the electrical conductors and switch, all of which were located in the exhaust air stream. A relocatable power tap was draped over the back shield of the down draft table. B. Easy Bench Model ALUM-BF1-MAT down draft table, serial number 1027947: The fan unit and its electrical wiring, including a switch connection, had titanium dust coated onto the electrical conductors and switch, all of which were located in the exhaust air stream. C. Two Craftsman 6 inch pedestal grinders: Titanium dust had migrated into the on/off switch enclosures. D. Wall mounted receptacles: Two standard wall mount electrical receptacles that were used to energize the two Craftsman and one Baldor pedestal grinding/buffing machines were found to contain dust from the grinding/buffing operation inside of the enclosures.
Recent events (2)
- · I (S) $2502.5
- · Z (S) $3850
1910.303 B07 I
- Issued
- Oct 31, 2014
- Penalty
- Initial $3,080 · Current $2,002 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: Main Hallway from Office to Plant: On, or about, May 27, 2014, a red piece of tape was used to cover the opening for the main breaker in Panel LP1, a Cutler-Hammer wall mounted circuit breaker box.
Recent events (2)
- · I (S) $2002
- · Z (S) $3080
1910.304 B04 II B
- Issued
- Oct 31, 2014
- Penalty
- Initial $3,080 · Current $2,002 Reduced
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4: Tool Crib: On, or about, May 27, 2014, a Sharp microwave oven and a Black & Decker toaster oven were energized through a relocatable power tap. The appliances energized through the power tap exceeded the maximum allowable load on the power tap.
Recent events (2)
- · I (S) $2002
- · Z (S) $3080
1910.304 G05
- Issued
- Oct 31, 2014
- Penalty
- Initial $3,850 · Current $2,503 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Turning Department: On, or about, May 27, 2014, a two-wire extension cord had been used to energize a grounded skimmer unit used for at the coolant tank on Machine #29, a Clausing milling center.
Recent events (2)
- · I (S) $2502.5
- · Z (S) $3850
1910.305 G01 IV A
- Issued
- Oct 31, 2014
- Penalty
- Initial $3,080 · Current $2,002 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Compressor Room: On, or about, May 27, 2014, extension cords were used to energize automatic drainage systems installed on each of the two Ingersoll-Rand air compressors.
Recent events (2)
- · I (S) $2002
- · Z (S) $3080
1910.146 C02
- Issued
- Oct 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: Compressor Room: On, or about, May 27, 2014, employees were not informed about the presence of a confined space by either signage, labels and/or stenciling on the steel plates that covered a pit that contained abandoned geothermal equipment.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.178 P01
- Issued
- Oct 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): Warehouse: On, or about, May 27, 2014, a weather cover had been attached to the overhead guard on the Crown forktruck that obstructed the operator's view through the guard.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Soldream, INC.
View Soldream, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336412)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339780868.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.