Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: BOARDMAN MOLDED PRODUCTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BOARDMAN MOLDED PRODUCTS in 1110 THAILA AVENUE, YOUNGSTOWN, OH 44512 (NAICS 326199). OSHA activity number 339782682.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Boardman Molded Products for free Get an email when a new federal OSHA severe-injury report for Boardman Molded Products is published. One employer, no account, unsubscribe in one click.
Site address
1110 THAILA AVENUE
City
YOUNGSTOWN
State
OH
ZIP
44512
Mailing
1110 THAILA AVENUE, YOUNGSTOWN, OH 44512
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
25
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 1, 2014
Abate by
Aug 21, 2014
Penalty
Initial $1,360 · Current $952 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    At the time of inspection, the employer did not ensure that the metal cutting band saw, MSC 518879 serial # 876684 was guarded.
Recent events (2)
  • · I (S) $952
  • · Z (S) $1360

1910.253 B04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2014
Abate by
Aug 21, 2014
Penalty
Initial $1,360 · Current $952 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    At the time of inspection, the employer did not ensure that acetylene and oxygen cylinders were separated while being stored.
Recent events (2)
  • · I (S) $952
  • · Z (S) $1360

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Aug 1, 2014
Abate by
Aug 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  At the time of inspection, the employer failed to install the plastic type junction boxes without knockouts.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Boardman Molded Products's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339782682.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.