ORLANDO, FL —
OSHA Inspection: ENVIROWASTE SERVICES GROUP, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ENVIROWASTE SERVICES GROUP, INC. in 1425 W. TAFT VINELAND RD., ORLANDO, FL 32837 (NAICS 541620). OSHA activity number 339783086.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENVIROWASTE SERVICES GROUP, INC.
- Site address
- 1425 W. TAFT VINELAND RD.
- City
- ORLANDO
- State
- FL
- ZIP
- 32837
- Mailing
- 4 SE 1 STREET 2ND FLOOR, MIAMI, FL 33131
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541620
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.146 D02
- Issued
- Jul 31, 2014
- Abate by
- Sep 22, 2014
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1910.146(d)(2): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not identify and evaluate the hazards of permit spaces before employees entered: a) N. Pine Hills Rd & SR 408, Orlando - The hazards of manholes were not identified and evaluated prior to employee entry, on or about May 22, 2014.
Recent events (2)
- — I (S) $2695
- — Z (S) $5390
1910.146 D05 I
- Issued
- Jul 31, 2014
- Abate by
- Sep 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(5)(i): Test conditions in the permit space to determine if acceptable entry conditions exist before entry is authorized to begin, except that, if isolation of the space is infeasible because the space is large or is part of a continuous system (such as a sewer), pre-entry testing shall be performed to the extent feasible before entry is authorized and, if entry is authorized, entry conditions shall be continuously monitored in the areas where authorized entrants are working: a) N. Pine Hills Rd & SR 408, Orlando - Manholes were not air monitored prior to employee entry, on or about May 22, 2014.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 D05 II
- Issued
- Jul 31, 2014
- Abate by
- Sep 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(5)(ii): Test or monitor the permit space as necessary to determine if acceptable entry conditions are being maintained during the course of entry operations: a) N. Pine Hills Rd & SR 408, Orlando - Manholes were not air monitored during employee entry, on or about May 22, 2014.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 E01
- Issued
- Jul 31, 2014
- Abate by
- Sep 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(e)(1): Before entry is authorized, the employer shall document the completion of measures required by paragraph (d)(3) of this section by preparing an entry permit: a) N. Pine Hills Rd & SR 408, Orlando - No permits were completed prior to manhole entry, on or about May22, 2014.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 G01
- Issued
- Jul 31, 2014
- Abate by
- Aug 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(g)(1): The employer shall provide training so that all employees whose work is regulated by this section acquire the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section: a) N. Pine Hills Rd & SR 408, Orlando - No training was provided to employees performing manhole entry, on or about May22, 2014.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.23 A06
- Issued
- Jul 31, 2014
- Abate by
- Sep 22, 2014
- Penalty
- Initial $9,240 · Current $4,620 Reduced
General-duty citation text
29 CFR 1910.23(a)(6): Every manhole floor opening shall be guarded by a standard manhole cover which need not be hinged in place. While the cover is not in place, the manhole opening shall be constantly attended by someone or shall be protected by removable standard railings: a) Dillsbury Court, Orlando, FL - No rails were used around the open manhole, on or about May 29, 2014. Envirowaste Services Group, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.23(a)(6), which was contained in OSHA inspection number 313107922, citation number 1, item number 1 and was affirmed as a final order on April 1, 2010, with respect to a workplace located at 1900 Liberty Avenue, Miami Beach, FL.
Recent events (2)
- — I (R) $4620
- — Z (R) $9240
More inspections at Envirowaste Services Group, INC.
View Envirowaste Services Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 541620)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339783086.