WHEELING, IL —
OSHA Inspection: ABSOLUTE TURN, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ABSOLUTE TURN, INC. in 1704 WOLF ROAD, WHEELING, IL 60090 (NAICS 332710). OSHA activity number 339783599.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ABSOLUTE TURN, INC.
- Site address
- 1704 WOLF ROAD
- City
- WHEELING
- State
- IL
- ZIP
- 60090
- Mailing
- 1704 WOLF ROAD, WHEELING, IL 60090
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 28
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C01
- Issued
- Jun 4, 2014
- Abate by
- Jun 30, 2014
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Facility Wide- The employer failed to establish a Lockout Tagout Program consisting of an energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on machines such as the Mazak Turning Machines or other equipment where the unexpected energization, startup or release of stored energy could occur and cause injury. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.178 L01 I
- Issued
- Jun 4, 2014
- Abate by
- Jun 30, 2014
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Assembly Area- The employer failed to ensure that powered industrial truck operators were competent to operate powered industrial trucks, such as the Toyota Forklift, Serial #19075, safely as demonstrated by the successful completion of the training and evaluation. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1910.303 B02
- Issued
- Jun 4, 2014
- Abate by
- Jun 30, 2014
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Machine Shop- The employer failed to ensure that electrical equipment, such as the multiple outlet gang boxes that were hanging from flexible conduit near Mazak 6200Y, Mazak VCS, Mazak Turn 20, and Mazak 6200, was being used as permitted under its listing and labeling. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
More inspections at Absolute Turn, INC.