Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: C & A PROPERTIES LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C & A PROPERTIES LLC in 115 ATLANTIC AVENUE, BROOKLYN, NY 11201 (NAICS 238140). OSHA activity number 339784373.

Watch C & A Properties LLC — free Get an email when a new federal OSHA severe-injury report for C & A Properties LLC is published. One employer, no account, unsubscribe in one click.
Site address
115 ATLANTIC AVENUE
City
BROOKLYN
State
NY
ZIP
11201
Mailing
9515 AVENUE N, BROOKLYN, NY 11236
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.1052 C05

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.1052(c)(5): Handrails and the top rails of stairrail systems shall be capable of withstanding, without failure, a force of at least 200 pounds (890 n) applied within 2 inches (5 cm) of the top edge, in any downward or outward direction, at any point along the top edge.    Site: 115 Atlantic Avenue Brooklyn, NY    On or about 5/28/14    a) The handrail on the stairway leading from the ground floor to the 2nd floor its not capable of withstanding a force of at least 200 pounds. It was held together with a cord.
Recent events (3)
  • — F (S) $1000
  • — C (S) $2000
  • — Z (S) $2000

1926.405 G02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $900.00 Reduced
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    Site: 115 Atlantic Avenue Brooklyn, NY    On or about 5/28/14    a)The cord from the circular saw had no strain relief and showed signs of strain.
Recent events (3)
  • — F (S) $900
  • — C (S) $1600
  • — Z (S) $1600

1926.405 J01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1926.405(j)(1)(ii): Support. Fixtures, lampholders, rosettes, and receptacles shall be securely supported. A fixture that weighs more than 6 pounds (2.72 kg) or exceeds 16 inches (406 mm) in any dimension shall not be supported by the screw shell of a lampholder.    Site: 115 Atlantic Avenue Brooklyn, NY    On or about 5/28/14    a) The outlet was not properly mounted or secure. It was just hanging by the staircase.
Recent events (3)
  • — F (S) $0
  • — C (S) $1600
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339784373.