ATLANTA, GA ·
OSHA Inspection: LEVENT INDUSTRIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LEVENT INDUSTRIES, INC. in 1130 D.L. HOLLOWELL PKWY, ATLANTA, GA 30318 (NAICS 541310). OSHA activity number 339784647.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEVENT INDUSTRIES, INC.
- Site address
- 1130 D.L. HOLLOWELL PKWY
- City
- ATLANTA
- State
- GA
- ZIP
- 30318
- Mailing
- 1130 D.L. HOLLOWELL PKWY, ATLANTA, GA 30318
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541310
- Employees
- 80
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.213 D01
- Issued
- Sep 22, 2014
- Abate by
- Oct 24, 2014
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: (a) Wood Department; The employer did not ensure that the Delta table saw was equipped with a guard. Employees were exposed to the 10" blade while cutting wood. (b) Wood Department; The employer did not ensure that the KUFO table saw was equipped with a guard. Employees were exposed to the blade while cutting wood.
Recent events (2)
- · I (S) $2940
- · Z (S) $4900
5(a)(1)
- Issued
- Sep 22, 2014
- Abate by
- Nov 7, 2014
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to explosion hazards and sharp particles flying in the air: a) Wood Department - Employees were exposed to flying plastic projectile hazards due to possible mechanical failure of the plastic polyvinyl chloride (PVC) piping system used to transport compressed air, exposing employees to serious physical hazards which could result in lacerations to the body and damage to the eyes resulting in hospitalization. Levent Industries, Inc. DBA Architectural Brass was previously cited for a violation of this occupational safety and health standard or its equivalent standard OSH ACT of 1970 Section (5)(a)(1), which was contained in OSHA inspection number 314640129, citation number 1, item number 1 and was affirmed as a final order on 2/24/12, with respect to a workplace located at 1130 D.L. Hollowell Pkwy., Atlanta, GA.
Recent events (2)
- · I (R) $4200
- · Z (R) $7000
1910.134 E01
- Issued
- Sep 22, 2014
- Abate by
- Oct 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Wood Department; the employer failed to provide medical evaluation to determine employee(s) ability to utilize a 3M N-95 particulate respirator (two strap dust mask). Employees were exposed to the hazard associated with the dust produced from the wood.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 F01
- Issued
- Sep 22, 2014
- Abate by
- Oct 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) Wood Department; the employer failed to provide respiratory fit testing for employees required to utilize a 3M N-95 particulate respirator (two strap dust mask). Employees were exposed to the hazard associated with the dust produced from the wood.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.305 G02 III
- Issued
- Sep 22, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) Wood Department; the employer did not ensure that the flexible cord that powers the Dayton Fan were connected to devices and fittings so that strain relief is provided. Employees were exposed to electric shock while connecting or disconnecting the fan to the outlet. (b) Wood Department; the employer did not ensure that the extension cord that powers the Porter-Cable Sander were connected to devices and fittings so that strain relief is provided. Employees were exposed to electric shock while connecting or disconnecting the sander to the outlet.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 541310)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339784647.