CHICAGO, IL —
OSHA Inspection: CRG CONTRACTORS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CRG CONTRACTORS in 7118 S. STONEY ISLAND AVE., CHICAGO, IL 60649 (NAICS 238140). OSHA activity number 339787863.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRG CONTRACTORS
- Site address
- 7118 S. STONEY ISLAND AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60649
- Mailing
- 8926 N. GREENWOOD AVE, #121, NILES, IL 60714
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1903.19 C01
- Issued
- Jan 6, 2015
- Abate by
- Feb 24, 2015
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1903.19(c)(1): Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section. a. On or about January 5, 2015 - the employer did not certify to OSHA within 10 days after the abatement date that each of the following cited violations issued had been corrected: Citation Number Item Number Abatement Date 01 001 10/23/2014 01 002 10/23/2014 01 003 10/23/2014
Recent events (1)
- — Z (O) $400
1926.451 E01
- Issued
- Oct 17, 2014
- Abate by
- Oct 23, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. a. On or about May 30, 2014 - at the above addressed jobsite, employees performing masonry operations from a tubular welded frame scaffold, approximately fourteen (14) feet eight (8) inches above the ground, were not provided with a safe means of access, thereby exposing employee to fall hazards.
Recent events (1)
- — Z (S) $2000
1926.451 F06
- Issued
- Oct 17, 2014
- Abate by
- Oct 23, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines: a. On or about May 30, 2014 - at the above addressed jobsite, employees were performing masonry operations from a tubular welded frame scaffold that was erected within ten (10) feet of uninsulated power lines, thereby exposing the employees to electrical hazards.
Recent events (1)
- — Z (S) $2000
1926.451 G01
- Issued
- Oct 17, 2014
- Abate by
- Oct 23, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. a. On or about May 30, 2014 - at the above addressed jobsite, employees were performing masonry operations from a tubular welded frame scaffold, approximately fourteen (14) feet eight (8) inches above the ground, that was not equipped with guardrails, thereby exposing the employees to fall hazards.
Recent events (1)
- — Z (S) $2800
More inspections at CRG Contractors
View CRG Contractors's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339787863.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.