Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CRG CONTRACTORS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CRG CONTRACTORS in 7118 S. STONEY ISLAND AVE., CHICAGO, IL 60649 (NAICS 238140). OSHA activity number 339787863.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CRG Contractors — free Get an email when a new federal OSHA severe-injury report for CRG Contractors is published. One employer, no account, unsubscribe in one click.
Establishment
CRG CONTRACTORS
Site address
7118 S. STONEY ISLAND AVE.
City
CHICAGO
State
IL
ZIP
60649
Mailing
8926 N. GREENWOOD AVE, #121, NILES, IL 60714
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

4 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 6 exposed
Issued
Jan 6, 2015
Abate by
Feb 24, 2015
Penalty
Initial $400 · Current $400
29 CFR 1903.19(c)(1): Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.  a. On or about January 5, 2015 - the employer did not certify to OSHA within 10 days after the abatement date that each of the following cited violations issued had been corrected:  Citation Number                Item Number                Abatement Date 01                                   001                             10/23/2014 01                                   002                             10/23/2014    01                                   003                             10/23/2014
Recent events (1)
  • — Z (O) $400

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 17, 2014
Abate by
Oct 23, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.  a. On or about May 30, 2014 - at the above addressed jobsite, employees performing masonry operations from a tubular welded frame scaffold, approximately fourteen (14) feet eight (8) inches above the ground, were not provided with a safe means of access, thereby exposing employee to fall hazards.
Recent events (1)
  • — Z (S) $2000

1926.451 F06

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 17, 2014
Abate by
Oct 23, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines:                       a. On or about May 30, 2014 - at the above addressed jobsite, employees were performing masonry operations from a tubular welded frame scaffold that was erected within ten (10) feet of uninsulated power lines, thereby exposing the employees to electrical hazards.
Recent events (1)
  • — Z (S) $2000

1926.451 G01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 17, 2014
Abate by
Oct 23, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.  a. On or about May 30, 2014 - at the above addressed jobsite, employees were performing masonry operations from a tubular welded frame scaffold, approximately fourteen (14) feet eight (8) inches above the ground, that was not equipped with guardrails, thereby exposing the employees to fall hazards.
Recent events (1)
  • — Z (S) $2800

View CRG Contractors's full OSHA safety record →