Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: AIR PRODUCTS AND CHEMICALS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of AIR PRODUCTS AND CHEMICALS, INC. in N10189 370TH STREET, BOYCEVILLE, WI 54725 (NAICS 325120). OSHA activity number 339788234.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIR Products and Chemicals, INC. for free Get an email when a new federal OSHA severe-injury report for AIR Products and Chemicals, INC. is published. One employer, no account, unsubscribe in one click.
Site address
N10189 370TH STREET
City
BOYCEVILLE
State
WI
ZIP
54725
Mailing
7201 HAMILTON BOULEVARD MC: A6212, ALLENTOWN, PA 18195
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325120
Employees
3
Ownership type
Private (A)

5 citations on file for this inspection.

1910.1000 E

Other-than-serious 1 instance 3 exposed
Issued
Sep 25, 2014
Abate by
Nov 17, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.1000(e):     Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):    a) N10189 370th Street, Boyceville, WI; The employer did not document adequately that the discharge from the receiver relief valve discharged to an appropriate location to control potential exposure to the contents of the receiver.
Recent events (3)
  • · F (O) $7000
  • · C (S) $7000
  • · Z (S) $7000

1910.1200 E01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Sep 25, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met (Construction Reference: 1926.59):  (a) N10189 370th Street Boyceville, WI; The employer did not develop, implement, and maintain at the workplace a written hazard communication program prior to employee exposure to worksite chemicals, specifically those hazards pertaining to anhydrous ammonia.
Recent events (3)
  • · F (S) $0
  • · C (S) $7000
  • · Z (S) $7000

1910.1200 H01

Other-than-serious 1 instance 3 exposed
Issued
Sep 25, 2014
Abate by
Oct 24, 2014
Penalty
Initial $0 · Current $7,000
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area(Construction Reference: 1926.59):     (a) N10189 370th Street Boyceville, WI; Prior to employee exposure, the employer did not provide information and training on the hazardous chemicals in their work area, specifically those hazards pertaining to anhydrous ammonia.
Recent events (3)
  • · F (O) $7000
  • · C (S) $0
  • · Z (S) $0

1926.20 B02

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Sep 25, 2014
Abate by
Oct 24, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):    (a) N10189 370th Street Boyceville, WI;  The competent person on-site did not adequately inspect the site equipment as a charged anhydrous ammonia high pressure receiver (s/n 951049) with a pressure relief valve relief point was located in immediate proximity to where employee(s) were working.     (b) N10189 370th Street Boyceville, WI; The competent person on-site did not adequately and regularly inspect the site to ensure equipment such as drench showers were properly placed, in that the shower station was placed directly near the anhydrous ammonia high pressure receiver so the employee exposed to anhydrous ammonia was not able to access the shower as the high pressure receiver was relieving.
Recent events (3)
  • · F (S) $0
  • · C (S) $7000
  • · Z (S) $7000

1910.120 Q01

Other-than-serious 1 instance 3 exposed
Issued
Sep 25, 2014
Penalty
Initial $6,600 · Current $6,600
29 CFR 1910.120(q)(1):     The emergency response plan was not in writing and was not available for inspection and copying by employees, their representatives, and OSHA personnel:    a) N10189 370th Street, Boyceville, WI; The employer did not have a written emergency action plan available onsite that indicated appropriate response to emergency situations, specifically those related to an anhydrous ammonia release.
Recent events (3)
  • · F (O) $6600
  • · C (S) $6600
  • · Z (S) $6600

View AIR Products and Chemicals, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339788234.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.