Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ASHLAND, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ASHLAND, INC. in 5200 BLAZER PARKWAY, DUBLIN, OH 43017 (NAICS 325188). OSHA activity number 339788853.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ashland, INC. — free Get an email when a new federal OSHA severe-injury report for Ashland, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ASHLAND, INC.
Site address
5200 BLAZER PARKWAY
City
DUBLIN
State
OH
ZIP
43017
Mailing
5200 BLAZER PARKWAY, DUBLIN, OH 43017
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325188
Employees
800
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 60 exposed
Issued
Jul 22, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.    a. At the site, the employer did not develop specific procedures for the control of potentially hazardous energy when employees performed maintenance and repair on the GS Manufacturing Over/Under Meter-Mix Dispensing Unit.  On or about 2/26/14 an employee sustained a finger amputation while servicing the machine.
Recent events (1)
  • — Z (S) $7000

1910.147 C04 II C

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 22, 2014
Abate by
Aug 1, 2014
Penalty
Initial $2,550 · Current $2,550
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  29 CFR 1910.147(c)(4)(ii)(C): Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.  a. At the site, the employer did not ensure that the specific lockout/tagout procedures developed included the removal of lock out devices when performing lockout procedures on the GS Manufacturing Over/under Meter Mix Dispensing Unit.