Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THE ADIDAS GROUP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THE ADIDAS GROUP in 10801 CORKSCREW ROAD SUITE C-116, ESTERO, FL 33928 (NAICS 453998). OSHA activity number 339789885.

Watch THE Adidas Group — free Get an email when a new federal OSHA severe-injury report for THE Adidas Group is published. One employer, no account, unsubscribe in one click.
Establishment
THE ADIDAS GROUP
Site address
10801 CORKSCREW ROAD SUITE C-116
City
ESTERO
State
FL
ZIP
33928
Mailing
5055 NORTH GREELEY AVENUE, PORTLAND, OR 97217
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
45000
Ownership type
A

2 citations on file for this inspection.

1910.36 G02

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  a) For employees working at 10801 Corkscrew Road #C116 in Estero, as observed on or about May 30, 2014. Employees were working in an office where the exit access was not at least 28 inches wide at all points. A cart was placed in the exit access allowing approximately 24 inch wide exit access.
Recent events (1)
  • — Z (O) $0

1910.303 G01 I A

Other-than-serious 1 instance 15 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:    a) For employees working at 10801 Corkscrew Road #C116 in Estero, as observed on or about May 30, 2014. Electrical panels in the hallway did not have the minimum depth requirements for access to the panel. The panels required a minimum of 3 feet clearance in accordance with Table S-1 of Subpart s of Part 1910 in and around the front of the panels. Employer stored a cart in front of the panels.
Recent events (1)
  • — Z (O) $0

TARGET