Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: TARPON ENERGY SERVICES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TARPON ENERGY SERVICES, LLC in 3381 ROAD 28 SOUTH, KIMBALL, NE 69145 (NAICS 335999). OSHA activity number 339791246.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tarpon Energy Services, LLC for free Get an email when a new federal OSHA severe-injury report for Tarpon Energy Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3381 ROAD 28 SOUTH
City
KIMBALL
State
NE
ZIP
69145
Mailing
9164 MARSHAL PLACE, WESTMINSTER, CO 80031
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335999
Employees
20
Ownership type
Private (A)

2 citations on file for this inspection.

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 27, 2014
Abate by
Oct 14, 2014
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system:    Trench from the Power Distribution Center to the Pump House on the jobsite located at 3381 Road 28 South, Kimball, NE: The employer is failing to protect employees from cave-ins while connecting PVC conduit at an approximate depth of 6 feet inside of the trench. The trench is approximately 45 feet long and varies in depths from 4 feet at the ends and 6 feet in the center. The employer failed to provide trench boxes, hydraulic shoring or implement another approved means of protection such but not limited to sloping or benching of the soil.
Recent events (2)
  • · I (S) $4900
  • · Z (S) $7000

1926.1053 B04

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 27, 2014
Abate by
Oct 14, 2014
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed:    Trench from the Power Distribution Center to the Pump House on the jobsite located at 3381 Road 28 South, Kimball, NE: The employer is failing to protect employees in that step ladders were being used in the folded position as means of egress during trenching/ excavation activities. Two, eight foot fiberglass step ladders were being used inside of a trench for egress during the inspection.     ANSI- A14.5-2007: 9.3.1.2- states that self-supporting ladders shall not be used as single ladders or in the partially closed position.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $5000

View Tarpon Energy Services, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339791246.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.