Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: C. H. GUENTHER & SON, INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C. H. GUENTHER & SON, INCORPORATED in 129 E. GUENTHER ST, SAN ANTONIO, TX 78204 (NAICS 311211). OSHA activity number 339791550.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C. H. Guenther & SON, Incorporated — free Get an email when a new federal OSHA severe-injury report for C. H. Guenther & SON, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
129 E. GUENTHER ST
City
SAN ANTONIO
State
TX
ZIP
78204
Mailing
P.O. BOX 118, SAN ANTONIO, TX 78291
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311211
Employees
150
Ownership type
A

6 citations on file for this inspection.

1910.212 B

Serious Gravity 5 2 instances 23 exposed
Issued
Sep 12, 2014
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    Within the machine maintenance shop, on or about June 3, 2012, the following fixed items of industrial equipment were found not to be securely anchored in order to prevent inadvertent or unforeseen walking or movement of the machinery:    a) Along the west wall of the machine maintenance shop a Manhattan MSC milling machine model YF-TM2 was not securely anchored.    b) Along the north wall of the machine maintenance shop a Vectrax MSC vertical band saw was not securely anchored.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.219 C04 II

Serious Gravity 10 1 instance 150 exposed
Issued
Sep 12, 2014
Abate by
Sep 27, 2014
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered:    On the north side along the of the walkway of the production section, on or about June 03, 2014, employees are exposed to a caught hazard from an overhead conveyor belt system with a rotating keyshaft located approximately seven feet from the ground.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1910.219 D01

Serious Gravity 10 1 instance 150 exposed
Issued
Sep 12, 2014
Abate by
Sep 27, 2014
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On the north side along the of the walkway of the production section, on or about June 03, 2014, employees are exposed to a caught hazard from an overhead conveyor belt system with moving pulleys located approximately seven feet from the ground.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1910.219 E02 I

Serious Gravity 10 1 instance 150 exposed
Issued
Sep 12, 2014
Abate by
Sep 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(2)(i): Overhead horizontal belt(s) with lower parts seven -7 feet or less from the floor(s) or platform(s) were not guarded on the sides and bottom in accordance with the requirements specified at CFR 1910.219(o)(3):  On the north side along the of the walkway of the production section, on or about June 03, 2014, employees are exposed to a caught hazard from an overhead conveyor belt system with moving horizontal belts located approximately seven feet from the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.254 D09 III

Serious Gravity 5 1 instance 23 exposed
Issued
Sep 12, 2014
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced:  Along the welding section of the machine shop, on or about June 03, 2014, a damaged welding cable lead with exposed bare conductors was being used, exposing the employee to an electrical shock hazard.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.305 B01 II

Serious Gravity 5 7 instances 23 exposed
Issued
Sep 12, 2014
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Along the west side wall of the machine maintenance shop, on or about June 03, 2014, and at times prior thereto, the following fixed power source enclosures, had unused openings along the bottom and sides of the electrical distribution panel boxes that were not effectively closed:  a) Along the west side wall of the machine maintenance shop, the fixed power enclosure controlling the electrical power to the Miller Syncrowave model 250 welding generator.  b) Along the west side wall of the machine maintenance shop, the fixed power enclosure controlling the electrical power to the Vectrax MSC model 09517350 lathe machine.  c) Along the west side wall of the machine maintenance shop, the fixed power enclosure controlling the electrical power to the Vectrax MSC model 09514639 vertical band saw.  d) Along the west side wall of the machine maintenance shop, the fixed power enclosure controlling the electrical power to the Manhattan MSC model YF-TM2 milling machine.  e) Along the west side wall of the machine maintenance shop, the fixed power enclosure controlling the electrical power to the battery charger system.  f) Along the west side wall of the machine maintenance shop, the fixed power enclosure controlling the electrical power to the plasma arc and blower system.  g) Along the west side wall of the machine maintenance shop, the fixed power enclosure controlling the electrical power to the electrical heater system.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

View C. H. Guenther & SON, Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339791550.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.