Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KING AG PRODUCTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KING AG PRODUCTS in 25584 N HIGHWAY 65, CARROLLTON, MO 64633 (NAICS 484110). OSHA activity number 339792418.

Watch King AG Products — free Get an email when a new federal OSHA severe-injury report for King AG Products is published. One employer, no account, unsubscribe in one click.
Establishment
KING AG PRODUCTS
Site address
25584 N HIGHWAY 65
City
CARROLLTON
State
MO
ZIP
64633
Mailing
25584 N HIGHWAY 65, CARROLLTON, MO 64633
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484110
Employees
18
Ownership type
A

8 citations on file for this inspection.

1910.106 E06 II

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $0.00 Reduced
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids , or Category 3 flammable liquids with a flashpoint below 100 degrees Fahrenheit (37.8 degrees Celsius) were not dispensed into containers unless the nozzle and the container were electrically interconnected.  Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.  (a)  Outdoor Storage Shed:  Employees were exposed to fire hazards, as the 55 gallon drum of Enamel Orange, and the 55 gallon drum of Xylene which were not bonded and grounded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1020

1910.178 L01 I

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $510.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  (a)  Production: Forklift operators have not received forklift training initially then at least once every three years.
Recent events (2)
  • — I (S) $510
  • — Z (S) $1020

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a)  Cutting/Bending Area:  Employees were exposed to amputation hazards as the Wysong Shear blade and hold downs were not guarded.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1910.212 A05

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:  (a) Paint Booth, North Wall:  Employees were exposed to amputation hazards as window fans which were within seven feet of the floor did not have guards.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1910.252 A02 VII

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1910.252(a)(2)(vii): Where practicable, combustible materials were not relocated at least 35 feet (10.7 m) from the cutting or welding operation work site:  (a) Dip Tank:  Employees were exposed to welding and grinding being conducted within 35 feet of the combustible paint.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.252 B02 III

Serious Gravity 5 24 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  (a) Final Weld Area, and Creep-Pen Weld Area:  Welders and other persons adjacent to the welding area were not protected from the rays by welding screens.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $0.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) Dip Tank Area:  Employees were exposed to electrical hazards as there was an open knockout on the top of the electrical panel to the right of the dip tank.  (b) Dip Tank Area: Employees were exposed to electrical hazards as there was an open knockout on the left side of the Cutler Hammer Control Box.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1020

1910.305 G02 III

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $0.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a) Cutting/Bending Area:  Employees were exposed to electrical hazards as the Wysong Shear did not have adequate strain relief, as the electrical cord where it attaches to the electrical control box as it had been damaged and taped with electrical tape.    (b) Cutting/Bending Area:  Employees were exposed to electrical hazards as the Wysong Shear did not have adequate strain relief, as the electrical cord where it attaches to the back motor that runs the back stop, the outer insulation had pulled back exposing interior wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1360