On , OSHA opened a planned safety inspection of CENTRIFUGAL CASTINGS, INC. in 3320 PARKWAY DRIVE, TEMPLE, TX 76503 (NAICS 331513). OSHA activity number 339793846.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENTRIFUGAL CASTINGS, INC.
- Site address
- 3320 PARKWAY DRIVE
- City
- TEMPLE
- State
- TX
- ZIP
- 76503
- Mailing
- P.O. BOX 210, TEMPLE, TX 76503
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331513
- Employees
- 60
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.106 E02 IV D
- Issued
- Aug 25, 2014
- Abate by
- Aug 29, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve. On or about 3 June 2014, and at times prior thereto, employees would use the ball valve on a 55 gallon drum dispenser of Mineral Spirit 300 to fill smaller containers without the use of a self-closing valve, exposing the employees to a fire and explosion hazard.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.132 A
- Issued
- Aug 25, 2014
- Abate by
- Dec 19, 2014
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered. On or about 3 June 2014, and at times prior thereto, employees performing melting activities were wearing FR clothing arc rated at 8.7 for shirts and 23.8 for pants, exposing those employees to a burn hazard from splashing or popping of molten metal onto their clothing.
Recent events (2)
- · I (S) $1750
- · Z (S) $3500
1910.133 A01
- Issued
- Aug 25, 2014
- Abate by
- Aug 29, 2014
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): Protective face equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment. On or about 3 June 2014, and at times prior thereto, two employees were working on a melting pot each in which at certain times, flux has to be added that may have rust on it, causing sparks to fly out during the melting process. During these times, the employees are wearing safety glasses but not a face shield or hard hats, exposing the workers to burns from being struck about the face and neck by hot sparks of molten metal.
Recent events (2)
- · I (S) $1750
- · Z (S) $3500
1910.135 A01
- Issued
- Aug 25, 2014
- Abate by
- Aug 29, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects. On or about 3 June 2014, and at times prior thereto, two employees were working on a melting pot each in which at certain times, flux has to be added that may have rust on it, causing sparks to fly out during the melting process. During these times, the employees are wearing safety glasses but not face shields and hard hats, exposing the workers to burns on the head from being struck by hot sparks of molten metal.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Centrifugal Castings, INC.
View Centrifugal Castings, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331513)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339793846.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.