OSHA Inspection: STERLING PAPER COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STERLING PAPER COMPANY in 2155 EAST CASTOR AVE, PHILADELPHIA, PA 19134 (NAICS 322212). OSHA activity number 339794414.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sterling Paper Company — free Get an email when a new federal OSHA severe-injury report for Sterling Paper Company is published. One employer, no account, unsubscribe in one click.
Site address
2155 EAST CASTOR AVE
City
PHILADELPHIA
State
PA
ZIP
19134
Mailing
2155 EAST CASTOR AVE, PHILADELPHIA, PA 19134
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322212
Employees
23
Ownership type
A

9 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 1 instance 8 exposed
Issued
Oct 20, 2014
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:    a) 2155 E.  Castor Ave, Philadelphia, PA  - Throughout the entire workplace - The employer did not ensure that the floors in every workroom were as dry as possible. This hazard exposed the employees to slip/fall hazards. This condition was observed on or about May 28, 2014.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.178 L06

Serious Gravity 1 1 instance 9 exposed
Issued
Oct 20, 2014
Abate by
Nov 6, 2014
Penalty
Initial $1,200 · Current $750 Reduced
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by paragraph (l) through a certification that included the name of the operator, the date of the training, that date of evaluation, and the identity of the person(s) performing the training or evaluation:    a) 2155 E.  Castor Ave, Philadelphia, PA  The employer did not ensure that each employee operating the Komatsu powered industrial truck was trained and evaluated. This condition exposed the employees to struck-by/caught in-between hazards. This condition was observed on or about May 28, 2014.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $750
  • — Z (S) $1200

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 20, 2014
Penalty
Initial $1,600 · Current $750 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees from the hazards created by rotating parts:    a) 2155 E.  Castor Ave, Philadelphia, PA - Zerand Department - An employee was not protected from the hazards created by an unguarded rotating chuck on the Rockwell drill press, Model #15-000, and Serial #1863199. This violation exposed the employee to rotating and or flying parts from material or bit, when in operation. This violation was observed on or about May 28, 2014.
Recent events (2)
  • — I (S) $750
  • — Z (S) $1600

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 20, 2014
Penalty
Initial $1,200 · Current $500 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    a) 2155 E.  Castor Ave, Philadelphia, PA  Zerand Department  An employee would operate the Ryobi 3,600 rpm bench grinder with the work rest not adjusted to within 1/8th inch of the abrasive wheel. The work rest was approximately ½ inch from the abrasive wheel. This hazard exposed the employee to struck-by/caught in-between hazards. This condition was observed on or about May 28, 2014.
Recent events (2)
  • — I (S) $500
  • — Z (S) $1200

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:  a) 2155 E.  Castor Ave, Philadelphia, PA  Zerand Department  An employee would operate the Ryobi 3,600 rpm bench grinder which did not have the peripheral protecting member 1/4th inch from the abrasive wheel, exposing the employee to a struck-by hazard. The peripheral protecting member was approximately 2 inches from the abrasive wheel. This violation was observed on or about May 28, 2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 20, 2014
Penalty
Initial $2,800 · Current $1,500 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) 2155 E.  Castor Ave, Philadelphia, PA  Zerand Department  The employees were using an energized (110 volt) pendant not in accordance to its listing and labeling, exposing the employees to a shock/electrocution hazard.  This condition was observed on or about May 28, 2014.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

1910.305 G02 III

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints and/or terminal screws:  a) 2155 E.  Castor Ave, Philadelphia, PA - The employees were using an energized (110 volt) pendant without having strain relief provided, exposing the employees to a shock/electrocution hazard. This condition was observed on May 28, 2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 20, 2014
Penalty
Initial $2,800 · Current $1,500 Reduced
29 CFR 1910.303(b)(7)(i): Unused opening in electrical cabinets were not effectively closed to provide substantially equivalent protection to the equipment:    a) 2155 E.  Castor Ave, Philadelphia, PA   Unused openings in electrical cabinets were not effectively closed or guarded against accidental contact. The energized (110/208 volts) circuit breaker panels were missing circuit breakers or blanks, exposing the energized bus bar. This hazard exposed the employees to a shock/electrocution hazard. This condition was observed on or about May 28, 2014.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

1910.304 G05

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 20, 2014
Penalty
Initial $2,800 · Current $1,500 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a) 2155 E.  Castor Ave, Philadelphia, PA  Conveyor/wrapper  The grounding path from the energized (240 volt) conveyor motor to the wall outlet was not continuous and permanent, exposing the employees to a shock/electrocution hazard. This condition was observed on or about May 28, 2014.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

View Sterling Paper Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339794414.