Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENERAL SERVICES INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GENERAL SERVICES INCORPORATED in 1838 3RD ST., NE, WASHINGTON, DC 20018 (NAICS 238910). OSHA activity number 339795429.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Services Incorporated — free Get an email when a new federal OSHA severe-injury report for General Services Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
1838 3RD ST., NE
City
WASHINGTON
State
DC
ZIP
20018
Mailing
3613 GEORGIA AVE., NW, WASHINGTON, DC 20010
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
15
Ownership type
A

8 citations on file for this inspection.

1926.21 B02

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jul 30, 2014
Abate by
Sep 16, 2014
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  a) Employees were exposed to numerous fall and electrical hazards with no training provided, on or about 6/5/14.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1926.403 D01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2014
Abate by
Aug 5, 2014
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted:  a) Employees were using an outlet box which was lying on the floor and not mounted to a secure surface, on or about 6/5/14.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.405 A02 II B

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2014
Abate by
Aug 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(B): Temporary wiring branch circuit conductors were not run as multiconductor cord, cable assemblies, open conductors, nor in raceways:  a) Employees were using a branch circuit in the basement which was lying on the floor exposing them to electrical hazards, on or about 6/5/14.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 D

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 30, 2014
Abate by
Aug 5, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(d): Panelboards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front:  a) Employees were exposed to electrical hazards in the basement of the structure due to an unguarded breaker panel, on or about 6/5/14.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.850 A

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 30, 2014
Abate by
Aug 11, 2014
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.850(a): Evidence in writing was not available that an engineering survey performed by a competent person had been performed prior to permitting employee(s) to start demolition operations:  a) Employees were exposed to hazards associated with partial demolition of the residence due to no demolish survey being conducted or provided, on or about 6/5/14.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.850 G

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jul 30, 2014
Abate by
Aug 5, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.850(g): Wall openings in a structure being demolished were not protected to a height of approximately 42 inches:  a) Employees setting braces on the third floor without fall protection were exposed to a fall hazard of approximately 23 feet 4 inches, on or about 6/5/14.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.850 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jul 30, 2014
Abate by
Aug 5, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.850(i): Floor openings, not used as material drops, were not covered with a material substantial enough to support the weight of the load to be imposed:  a) Employees were exposed on all levels of the residence to floor holes creating fall hazards from approximately 7 feet 7 inches to approximately 23 feet 4 inches, on or about 6/5/14.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.851 B

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Jul 30, 2014
Abate by
Aug 5, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.851(b): All stairs, passageways, ladders and incidental equipment thereto, which are covered by this section, were not periodically inspected and maintained in a clean safe condition:  a) Employees used a set of stairs from the first to second floor, 16 risers in height, without stair rails exposed to fall hazards due to no stair rail, on or about 6/5/14.  b) Employees used a set of stairs from the second to the third floor, 14 risers in height, without stair rails exposed to fall hazards due to no stair rail, on or about 6/5/14.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

View General Services Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339795429.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.