Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: GEA RAINEY HEAT EXCHANGERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GEA RAINEY HEAT EXCHANGERS, INC. in 5202 W. CHANNEL RD., CATOOSA, OK 74015 (NAICS 333415). OSHA activity number 339796138.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GEA Rainey Heat Exchangers, INC. — free Get an email when a new federal OSHA severe-injury report for GEA Rainey Heat Exchangers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5202 W. CHANNEL RD.
City
CATOOSA
State
OK
ZIP
74015
Mailing
5202 W. CHANNEL RD., CATOOSA, OK 74015
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
235
Ownership type
A

12 citations on file for this inspection.

1910.106 D02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 15, 2014
Abate by
Jul 23, 2014
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.106(d)(2)(i):  Approved container(s) or portable tank(s) were not used for the storage of flammable or combustible liquids:    On or about June 10, 2014, and at times prior thereto, in the paint areas non approved containers without a self-closing lid were observed being used inside the building to handle and store C6 Lacquer Thinner having flash point of 81 degrees F exposing employees to fire hazards.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.106 E06 II

Serious Gravity 1 2 instances 17 exposed
Issued
Jul 15, 2014
Abate by
Jul 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(ii):  Class I flammable liquid(s) were dispensed into containers, vehicles, and equipment without electrically interconnecting the nozzle and the container, vehicles, or equipment:    On or about June 10, 2014, and at times prior thereto, in the paint areas and gasoline tank areas C6 Lacquer Thinner and gasoline were dispensed into another container and vehicle without being effectively grounded and bonded to electrically interconnect the containers and vehicle to prevent static discharge during dispensing operation exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 C06

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 15, 2014
Abate by
Aug 27, 2014
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.107(c)(6): Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spray area, and not separated therefrom by partitions, produced sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations:     On or about June 10, 2014, and at times prior thereto, in the paint areas electrical outlets, disconnect device and a fan observed within 20 feet of spraying area were not the type approved for Class I, Division 2, hazardous locations.  Employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.107 G05

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 15, 2014
Abate by
Aug 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(5): The use of solvents for cleaning operations was not restricted to those having flashpoints not less than 100 degrees F or the solvents having flashpoints not less than those normally used in the spray operation:      On or about June 10, 2014, and at times prior thereto, in the spray paint areas employees were using C6 lacquer thinner having flashpoint of 81 degrees F as a solvent for cleaning operations.  This exposes employees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 I

Serious Gravity 5 7 instances 15 exposed
Issued
Jul 15, 2014
Abate by
Aug 27, 2014
Penalty
Initial $3,060 · Current $1,836 Reduced
29 CFR 1910.179(i): Crane(s) equipped with a power traveling mechanism were not provided with a gong or other effective warning signal:    On or about June 5, 2014, and at times prior thereto, in the assembly area of Bldg. #1 and in Bldg. #5 overhead cranes were operated by a remote control device to lift heavy steel parts were not provided with the means (audible alarm or strobe light) to warn employees working in the areas when the cranes were on the move.  Employees were exposed to struck-by hazards.
Recent events (2)
  • — I (S) $1836
  • — Z (S) $3060

1910.212 A01

Serious Gravity 5 2 instances 5 exposed
Issued
Jul 15, 2014
Abate by
Jul 23, 2014
Penalty
Initial $3,825 · Current $2,295 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about June 11, 2014, and at times prior thereto, in Bldg. #5 two chop saws were observed being used without blade a guard provided to prevent contact with the operating blade.  Employees were exposed to an amputation caused by the unguarded blades.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $3825

1910.217 C01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 15, 2014
Abate by
Jul 30, 2014
Penalty
Initial $3,825 · Current $2,295 Reduced
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):    On or about June 11, 2014, and at times prior thereto, in the blade assembly areas in Bldg. #2 employees were operating a mechanical power press which had guard openings so big where employee's hands can enter the point-of-operation.  Employees were exposed to an amputation caused by the press while in operation.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $3825

1910.219 F03

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 15, 2014
Abate by
Aug 6, 2014
Penalty
Initial $3,825 · Current $2,295 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:    On or about June 11, 2014, and at times prior thereto, at the roller area in Bldg. #2 employees were operating a roller driven by a sprocket wheel, chain, and gear system approximately 2.5-ft. from the floor without a guard provided to prevent employee contact while in operation.  Employees were exposed to an amputation hazards.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $3825

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 15, 2014
Abate by
Jul 17, 2014
Penalty
Initial $3,060 · Current $1,836 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:    On or about June 4, 2014, and at time prior thereto, in the tri-bevel area an employee was working near a 440-Volt electrical panel which had the doors left open.  The employee was exposed to 440-Volt live electrical.
Recent events (2)
  • — I (S) $1836
  • — Z (S) $3060

1910.304 B02

Serious Gravity 1 4 instances 9 exposed
Issued
Jul 15, 2014
Abate by
Jul 21, 2014
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served:    On or about June 11, 2014, or at times prior thereto, in the mid bay welding areas in Bldg. #1 and in the break areas in Bldg. #2 were observed having electrical equipment plugged into the same outlet device which had a current rating less than the load being served.  This exposed employees to fire hazards.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.305 G01 IV A

Serious Gravity 1 1 instance 5 exposed
Issued
Jul 15, 2014
Abate by
Jul 21, 2014
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    On or about June 11, 2014, and at times prior thereto, in the break area in Bldg. #2 and through out facility electrical extension cords were found being used as a substitute for fixed wiring of a structure.  The employees were exposed fire hazards.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.134 G01 I A

Other-than-serious 1 instance 1 exposed
Issued
Jul 15, 2014
Abate by
Jul 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:    On or about June 10, 2014, and at times prior thereto, in the spray paint area an employee was required to wear a respirator without a proper seal due to facial hair.  Employees were exposed to respiratory hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339796138.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.