CATOOSA, OK —
OSHA Inspection: GEA RAINEY HEAT EXCHANGERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GEA RAINEY HEAT EXCHANGERS, INC. in 5202 W. CHANNEL RD., CATOOSA, OK 74015 (NAICS 333415). OSHA activity number 339796138.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GEA RAINEY HEAT EXCHANGERS, INC.
- Site address
- 5202 W. CHANNEL RD.
- City
- CATOOSA
- State
- OK
- ZIP
- 74015
- Mailing
- 5202 W. CHANNEL RD., CATOOSA, OK 74015
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 235
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.106 D02 I
- Issued
- Jul 15, 2014
- Abate by
- Jul 23, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.106(d)(2)(i): Approved container(s) or portable tank(s) were not used for the storage of flammable or combustible liquids: On or about June 10, 2014, and at times prior thereto, in the paint areas non approved containers without a self-closing lid were observed being used inside the building to handle and store C6 Lacquer Thinner having flash point of 81 degrees F exposing employees to fire hazards.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.106 E06 II
- Issued
- Jul 15, 2014
- Abate by
- Jul 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers, vehicles, and equipment without electrically interconnecting the nozzle and the container, vehicles, or equipment: On or about June 10, 2014, and at times prior thereto, in the paint areas and gasoline tank areas C6 Lacquer Thinner and gasoline were dispensed into another container and vehicle without being effectively grounded and bonded to electrically interconnect the containers and vehicle to prevent static discharge during dispensing operation exposing employees to a fire hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 C06
- Issued
- Jul 15, 2014
- Abate by
- Aug 27, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spray area, and not separated therefrom by partitions, produced sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations: On or about June 10, 2014, and at times prior thereto, in the paint areas electrical outlets, disconnect device and a fan observed within 20 feet of spraying area were not the type approved for Class I, Division 2, hazardous locations. Employees were exposed to fire hazards.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.107 G05
- Issued
- Jul 15, 2014
- Abate by
- Aug 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(5): The use of solvents for cleaning operations was not restricted to those having flashpoints not less than 100 degrees F or the solvents having flashpoints not less than those normally used in the spray operation: On or about June 10, 2014, and at times prior thereto, in the spray paint areas employees were using C6 lacquer thinner having flashpoint of 81 degrees F as a solvent for cleaning operations. This exposes employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 I
- Issued
- Jul 15, 2014
- Abate by
- Aug 27, 2014
- Penalty
- Initial $3,060 · Current $1,836 Reduced
General-duty citation text
29 CFR 1910.179(i): Crane(s) equipped with a power traveling mechanism were not provided with a gong or other effective warning signal: On or about June 5, 2014, and at times prior thereto, in the assembly area of Bldg. #1 and in Bldg. #5 overhead cranes were operated by a remote control device to lift heavy steel parts were not provided with the means (audible alarm or strobe light) to warn employees working in the areas when the cranes were on the move. Employees were exposed to struck-by hazards.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.212 A01
- Issued
- Jul 15, 2014
- Abate by
- Jul 23, 2014
- Penalty
- Initial $3,825 · Current $2,295 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about June 11, 2014, and at times prior thereto, in Bldg. #5 two chop saws were observed being used without blade a guard provided to prevent contact with the operating blade. Employees were exposed to an amputation caused by the unguarded blades.
Recent events (2)
- — I (S) $2295
- — Z (S) $3825
1910.217 C01 I
- Issued
- Jul 15, 2014
- Abate by
- Jul 30, 2014
- Penalty
- Initial $3,825 · Current $2,295 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): On or about June 11, 2014, and at times prior thereto, in the blade assembly areas in Bldg. #2 employees were operating a mechanical power press which had guard openings so big where employee's hands can enter the point-of-operation. Employees were exposed to an amputation caused by the press while in operation.
Recent events (2)
- — I (S) $2295
- — Z (S) $3825
1910.219 F03
- Issued
- Jul 15, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $3,825 · Current $2,295 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: On or about June 11, 2014, and at times prior thereto, at the roller area in Bldg. #2 employees were operating a roller driven by a sprocket wheel, chain, and gear system approximately 2.5-ft. from the floor without a guard provided to prevent employee contact while in operation. Employees were exposed to an amputation hazards.
Recent events (2)
- — I (S) $2295
- — Z (S) $3825
1910.303 G02 I
- Issued
- Jul 15, 2014
- Abate by
- Jul 17, 2014
- Penalty
- Initial $3,060 · Current $1,836 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision: On or about June 4, 2014, and at time prior thereto, in the tri-bevel area an employee was working near a 440-Volt electrical panel which had the doors left open. The employee was exposed to 440-Volt live electrical.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.304 B02
- Issued
- Jul 15, 2014
- Abate by
- Jul 21, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: On or about June 11, 2014, or at times prior thereto, in the mid bay welding areas in Bldg. #1 and in the break areas in Bldg. #2 were observed having electrical equipment plugged into the same outlet device which had a current rating less than the load being served. This exposed employees to fire hazards.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.305 G01 IV A
- Issued
- Jul 15, 2014
- Abate by
- Jul 21, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about June 11, 2014, and at times prior thereto, in the break area in Bldg. #2 and through out facility electrical extension cords were found being used as a substitute for fixed wiring of a structure. The employees were exposed fire hazards.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.134 G01 I A
- Issued
- Jul 15, 2014
- Abate by
- Jul 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: On or about June 10, 2014, and at times prior thereto, in the spray paint area an employee was required to wear a respirator without a proper seal due to facial hair. Employees were exposed to respiratory hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333415)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339796138.