CROYDON, PA —
OSHA Inspection: GENERAL PARTITION CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GENERAL PARTITION CO., INC. in 916 WASHINGTON AVE., CROYDON, PA 19021 (NAICS 322211). OSHA activity number 339796914.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENERAL PARTITION CO., INC.
- Site address
- 916 WASHINGTON AVE.
- City
- CROYDON
- State
- PA
- ZIP
- 19021
- Mailing
- 916 WASHINGTON AVE., CROYDON, PA 19021
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322211
- Employees
- 30
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C01
- Issued
- Sep 8, 2014
- Abate by
- Sep 25, 2014
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Production Work Area: On or about June 5, 2014, employees maintain and operate two guillotine machines with multiple sources of hazardous energy, to include but not limited to electricity and gravity, where specific Lockout/Tagout procedures are used, but the employer had not established an Energy Control Program to prevent employee injury.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.147 C07 I B
- Issued
- Sep 8, 2014
- Abate by
- Sep 25, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a) Production Work Area: On or about June 5, 2014, affected level employees were operating two guillotine machines which required the application of Lockout/Tagout hardware and procedures during maintenance, but had not received training to prevent potential injury during these activities.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Sep 8, 2014
- Abate by
- Sep 25, 2014
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Production Work Area, A Partition Stripper Machine (#12): On or about June 5, 2014, an employee was observed using an A Partition Stripper Machine (#12) with an unguarded blade, which exposed the employee to potential laceration injuries.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.219 D01
- Issued
- Sep 8, 2014
- Abate by
- Sep 25, 2014
- Penalty
- Initial $2,100 · Current $1,575 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Production Work Area, Automatic Multi-cell Fiber Partition Assembler Machine: On or about June 5, 2014, employees operating an Automatic Multi-cell Fiber Partition Assembler Machine were exposed to potential injury caused by ingoing nip points created by unguarded pulleys.
Recent events (2)
- — I (S) $1575
- — Z (S) $2100
1910.219 E03 I
- Issued
- Sep 8, 2014
- Abate by
- Sep 25, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o) (a) Production Work Area, Automatic Multi-cell Fiber Partition Assembler Machine: On or about June 5, 2014, employees operating an Automatic Multi-cell Fiber Partition Assembler Machine were exposed to potential injury caused by ingoing nip points created by an unguarded vertical belt.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 D01
- Issued
- Sep 8, 2014
- Abate by
- Sep 25, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. a) Production Work Area: On or about June 5, 2014, the employee break area is located under an above ground storage area where the load capacity is not marked.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at General Partition CO., INC.
View General Partition CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322211)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339796914.