Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: NIPRO GLASS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NIPRO GLASS in 1633 WHEATON AVENUE, MILLVILLE, NJ 08332 (NAICS 327213). OSHA activity number 339798589.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nipro Glass for free Get an email when a new federal OSHA severe-injury report for Nipro Glass is published. One employer, no account, unsubscribe in one click.
Establishment
NIPRO GLASS
Site address
1633 WHEATON AVENUE
City
MILLVILLE
State
NJ
ZIP
08332
Mailing
1633 WHEATON AVENUE, MILLVILLE, NJ 08332
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327213
Employees
450
Ownership type
Private (A)

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 8, 2014
Abate by
Nov 4, 2014
Penalty
Initial $7,000 · Current $5,250 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as melting excess glass:  a)  Nipro Glass Americas,  S tank - Hot box:  Employees were exposed to burning hazards while working around the S tank - hot Box chute,  observed on or about 6/3/2014.
Recent events (2)
  • · I (S) $5250
  • · Z (S) $7000

1910.157 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 8, 2014
Abate by
Nov 4, 2014
Penalty
Initial $3,000 · Current $2,250 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) Manufacturing facility - S box furnace: The employer had a portable fire extinguisher that was not mounted to the wall, on or about 06/03/2014.
Recent events (2)
  • · I (S) $2250
  • · Z (S) $3000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339798589.