MILLVILLE, NJ ·
OSHA Inspection: NIPRO GLASS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NIPRO GLASS in 1633 WHEATON AVENUE, MILLVILLE, NJ 08332 (NAICS 327213). OSHA activity number 339798589.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NIPRO GLASS
- Site address
- 1633 WHEATON AVENUE
- City
- MILLVILLE
- State
- NJ
- ZIP
- 08332
- Mailing
- 1633 WHEATON AVENUE, MILLVILLE, NJ 08332
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327213
- Employees
- 450
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Oct 8, 2014
- Abate by
- Nov 4, 2014
- Penalty
- Initial $7,000 · Current $5,250 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as melting excess glass: a) Nipro Glass Americas, S tank - Hot box: Employees were exposed to burning hazards while working around the S tank - hot Box chute, observed on or about 6/3/2014.
Recent events (2)
- · I (S) $5250
- · Z (S) $7000
1910.157 C01
- Issued
- Oct 8, 2014
- Abate by
- Nov 4, 2014
- Penalty
- Initial $3,000 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Manufacturing facility - S box furnace: The employer had a portable fire extinguisher that was not mounted to the wall, on or about 06/03/2014.
Recent events (2)
- · I (S) $2250
- · Z (S) $3000
More inspections in this industry (NAICS 327213)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339798589.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.