LOCKPORT, NY ·
OSHA Inspection: FW ROBERTS MANUFACTURING CO
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FW ROBERTS MANUFACTURING CO in 73 LOCK STREET, LOCKPORT, NY 14094 (NAICS 332996). OSHA activity number 339800013.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FW ROBERTS MANUFACTURING CO
- Site address
- 73 LOCK STREET
- City
- LOCKPORT
- State
- NY
- ZIP
- 14094
- Mailing
- 73 LOCK STREET, LOCKPORT, NY 14094
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.151 C
- Issued
- Sep 5, 2014
- Abate by
- Sep 29, 2014
- Penalty
- Initial $1,800 · Current $1,350 Reduced
General-duty citation text
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use: a) On or about 6/10/14, in the shop area, an eye wash station was not available for employee immediate use while working with corrosive material such as but not limited to: Producto SP-845 (pH 12.6) and Mereco MRC 03-1304 Activator (burns to skin). ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1350
- · Z (S) $1800
1910.178 L04 III
- Issued
- Sep 5, 2014
- Abate by
- Sep 29, 2014
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. a) On or about 6/10/14, in the establishment, an evaluation of each power industrial truck operator performance was not conducted at least once every three years. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $810
- · Z (S) $1080
1910.212 A01
- Issued
- Sep 5, 2014
- Abate by
- Sep 29, 2014
- Penalty
- Initial $1,800 · Current $1,350 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. a) On or about 6/10/14, in the upper shop area, a Gear hob machine was not adequate guarded and the Diamond cutter machine was missing the guard. b) On or about 6/10/14, in the lower part of the shop, the lathes machines were missing guards. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1350
- · Z (S) $1800
1910.147 C01
- Issued
- Sep 5, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) On or about 6/10/14, employer did not establish a written energy control program(LOTO) for employees performing maintenance and service on machines/equipment. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 E01
- Issued
- Sep 5, 2014
- Abate by
- Sep 29, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: a) On or about 6/10/14, employer did not develop a written hazard communication program, employees were exposed to corrosive material such as but not limited to; SP-845 with a pH of 12.6 and Merco MRC 03-1304 Activator which can result in burns to the employees. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 332996)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339800013.