On , OSHA opened a planned safety inspection of RUBEN RUIZ in 305 W. 6 ST., HOUSTON, TX 77007 (NAICS 238130). OSHA activity number 339801318.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RUBEN RUIZ
- Site address
- 305 W. 6 ST.
- City
- HOUSTON
- State
- TX
- ZIP
- 77007
- Mailing
- 4701 ANDERSON RD #241, HOUSTON, TX 77053
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 C02
- Issued
- Jun 18, 2014
- Abate by
- Jul 3, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation. The employer does not ensure that scaffold legs bear on base plates and mud sills other adequate firm foundation. a. This violation was observed on or about June 09, 2014 on the south side of the job site where employees were exposed to an approximate 15 foot fall hazard when working on an elevated pump jack scaffold without base plates and mud sills or other adequate firm foundation. b. This violation was observed on or about June 09, 2014 on the east side of the job site between two residential buildings where employees was exposed to an approximate 30 foot fall hazard when working on an elevated pump jack scaffold without base plates and mud sills or other adequate firm foundation. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all scaffold legs bear on base plates and mud sills or other adequate firm foundation.
Recent events (1)
- — Z (S) $2800
1926.452 J02
- Issued
- Jun 18, 2014
- Abate by
- Jul 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. The employer does not secure the scaffold poles to the structure at the bottom, top, and other points as necessary. a. This violation was observed on or about June 09, 2014 on the south side of the job site where employees were exposed to an approximate 15 foot fall hazard when working on an elevated pump jack scaffold without the scaffold being secured at the bottom, top, and other points as necessary. b. This violation was observed on or about June 09, 2014 on the east side of the job site between two residential buildings where employees was exposed to an approximate 30 foot fall hazard when working on an elevated pump jack scaffold without the scaffold being secured at the bottom, top, and other points as necessary. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure scaffold poles are secured to the structure by rigid triangular bracing at the bottom, top, and other points as necessary.
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Jun 18, 2014
- Abate by
- Jul 3, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. The employer does not protect employees from falling when working on scaffold more than 10 feet above a lower level. a. This violation was observed on or about June 9, 2014 on the south side of the residential building where employees were exposed to a fall hazard when working on an elevated pump jack scaffold at approximately 15 feet above the ground without being protected from falling to the ground. b. This violation was observed on or about June 9, 2014 on the east side of the residential building where employees were exposed to a fall hazard when working on an elevated pump jack scaffold at approximately 30 feet above the ground without being protected from falling to the ground. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all employees working from a scaffold 10 feet or more above a lower level are protected from falling.
Recent events (1)
- — Z (S) $2800
More inspections at Ruben Ruiz
View Ruben Ruiz's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339801318.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.