GLENVILLE, NY —
OSHA Inspection: ADIRONDACK LANDSCAPING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ADIRONDACK LANDSCAPING, INC. in SALVATION ARMY 282 SARATOGA ROAD, GLENVILLE, NY 12302 (NAICS 238130). OSHA activity number 339803363.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADIRONDACK LANDSCAPING, INC.
- Site address
- SALVATION ARMY 282 SARATOGA ROAD
- City
- GLENVILLE
- State
- NY
- ZIP
- 12302
- Mailing
- 1008 PLEASANTVIEW AVENUE, SCOTIA, NY 12302
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.20 B02
- Issued
- Jun 16, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person: (a) Front of the Building - on or about May 30, 2014 - the worksite was not inspected by a competent person that was designated by the employer. Observed hazards include improper ladder set-up, no fall protection from an elevated work area and an electrical hazard.
Recent events (1)
- — Z (S) $1600
1926.404 B01 I
- Issued
- Jun 16, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: (a) Front of the Building - on or about May 30, 2014 - electric tools were not protected by a Ground Fault Circuit Interrupter (GFCI). The employer did not use an Assured Equipment Grounding Conductor Program.
Recent events (1)
- — Z (S) $1200
1926.501 B01
- Issued
- Jun 16, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: (a) Front of the Building - on or about May 30, 2014 - no fall protection was available for the employees that were performing framing installations to the front of the building. Working elevation was approximately 12 feet, 1 inch.
Recent events (1)
- — Z (S) $1600
1926.503 A01
- Issued
- Jun 16, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Front of the Building - on or about May 30, 2014 - the employer did not provide fall protection training to the employees that were performing framing work. Working elevation was approximately 12 feet, 1 inch.
Recent events (1)
- — Z (S) $0
1926.1053 B01
- Issued
- Jun 16, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Front of the Building - on or about May 30, 2014 - the access ladder to the elevated deck did not extend the requisite three-feet above the upper work surface. Working elevation was approximately 12 feet, 1 inch.
Recent events (1)
- — Z (S) $1600
1926.1060 A01 V
- Issued
- Jun 16, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a)(1)(v): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the standards contained in Subpart X: (a) Front of the Building - on or about May 30, 2014 - the access ladder to the elevated deck did not extend the requisite three-feet above the upper work surface. Working elevation was approximately 12 feet, 1 inch.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238130)