HACKENSACK, NJ —
OSHA Inspection: DIAMOND RENOVATIONS & ADDITIONS, LLC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of DIAMOND RENOVATIONS & ADDITIONS, LLC. in 61 KANSAS STREET, HACKENSACK, NJ 07601 (NAICS 236118). OSHA activity number 339804353.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIAMOND RENOVATIONS & ADDITIONS, LLC.
- Site address
- 61 KANSAS STREET
- City
- HACKENSACK
- State
- NJ
- ZIP
- 07601
- Mailing
- 49 DIAMOND WAY, MOONACHIE, NJ 07074
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.300 B01
- Issued
- Jul 8, 2014
- Penalty
- Initial $2,000 · Current $800 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Building Exterior Front: Employees using an 18V Dewalt portable hand-held cordless saw that was not equipped with a safety guard, on or about 6/16/14.
Recent events (2)
- — I (S) $800
- — Z (S) $2000
1926.451 B01
- Issued
- Jul 8, 2014
- Penalty
- Initial $2,800 · Current $600 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii). a) Building Exterior Front: Employees were working from a fabricated frame scaffold, six frames in height, at approximately 33 feet above the lower surface, that was not fully planked, on or about 6/12/14.
Recent events (2)
- — I (S) $600
- — Z (S) $2800
1926.451 C01 II
- Issued
- Jul 8, 2014
- Penalty
- Initial $2,800 · Current $600 Reduced
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. a) Building Exterior Front: Employees were working from a fabricated frame scaffold, six frames in height, at approximately 33 feet above the lower surface, that was not secured to the building, on or about 6/12/14.
Recent events (2)
- — I (S) $600
- — Z (S) $2800
1926.451 E01
- Issued
- Jul 8, 2014
- Penalty
- Initial $2,800 · Current $500 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. a) Building Exterior Front: Employees climbed from a Marklift self-propelled scissor lift, raised approximately 33 feet in height from the lower surface, to access the working platform of a nearby fabricated frame scaffold, on or about 6/12/14.
Recent events (2)
- — I (S) $500
- — Z (S) $2800
1926.451 G04 I
- Issued
- Jul 8, 2014
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. a) Building Exterior Front: Employees were working from a fabricated frame scaffold, six frames in height, at approximately 33 feet above the lower surface, without a standard guardrail system, on or about 6/12/14. b) Building Exterior Front: An employee was working from the top of a plank that was positioned on the mid rail of a Marklift self-propelled scissor lift, raised approximately 33 feet above the lower surface, without a standard guardrail system, on or about 6/12/14. c) Building Exterior Front: Employees were working from a Marklift self-propelled scissor lift, raised approximately 33 feet above the lower surface, without a standard guardrail system from the front section of the scaffold facing the building, on the section on or about 6/12/14.
Recent events (2)
- — I (S) $1000
- — Z (S) $2800
1926.452 C02
- Issued
- Jul 8, 2014
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a) Building Exterior Front: Employees were working from a fabricated frame scaffold, six frames in height, at approximately 33 feet above the lower surface, that was missing cross braces from the interior side of the scaffold, on or about 6/12/14.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
More inspections at Diamond Renovations & Additions, LLC.
View Diamond Renovations & Additions, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339804353.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.