Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: ADVANCED RECOVERY INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ADVANCED RECOVERY INC in 50 GRAFTON AVE, NEWARK, NJ 07104 (NAICS 423930). OSHA activity number 339804627.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Recovery INC for free Get an email when a new federal OSHA severe-injury report for Advanced Recovery INC is published. One employer, no account, unsubscribe in one click.
Site address
50 GRAFTON AVE
City
NEWARK
State
NJ
ZIP
07104
Mailing
50 GRAFTON AVE, NEWARK, NJ 07104
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
10
Ownership type
Private (A)

10 citations on file for this inspection.

1910.36 D02

Serious Gravity 5 3 instances 6 exposed
Issued
Aug 4, 2014
Abate by
Aug 28, 2014
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.36(d)(2): Exit route doors must be free of any device or alarm that could restrict emergency use of the exit route if the device or alarm fails.    a) Warehouse    Exit route door was secured with two slide bolts restricting emergency use of exit.    b)  Exit route door next to office    Exit route door was locked with roll down metal door restricting emergency use of exit.    c)  Office door    Office door marked as exit route door was locked on both sides restricting emergency use.    Observed on or about 6/12/2014.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1600

1910.37 B04

Serious Gravity 5 1 instance 8 exposed
Issued
Aug 4, 2014
Abate by
Sep 19, 2014
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:    a) Warehouse/Storage area    Exit signs were not posted  in the warehouse and storage area indicating the direction of travel to the nearest exit and exit discharge.    Condition observed on or about 06/12/2014.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1600

1910.101 B

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 4, 2014
Abate by
Aug 28, 2014
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    a)Warehouse    Employee(s) working in warehouse were exposed to physical injury from compressed acetylene cylinders not properly secured.    Observed on or about 6/12/2014.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1600

1910.178 I01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 4, 2014
Abate by
Sep 19, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.178(i)(1): Concentration levels of carbon monoxide gas created by powered industrial truck operations exceeded the levels specified in 1910.1000:    a)  Warehouse    Clark LP gas and Kolmar AC LP gas powered industrial trucks were not maintained properly exposing employees to carbon monoxide found in vehicle exhaust, at levels of 1920ppm to over 2000ppm.     Observed on or about 06/12/2014.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.178 L03 II H

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 4, 2014
Abate by
Sep 19, 2014
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1910.178(l)(3)(ii)(H):  Powered industrial truck operators did not receive training in the hazards of closed environments and other areas where insufficient ventilation or poor vehicle maintenance could cause a buildup of carbon monoxide.    a)  Warehouse    Employees who operate Clark LP gas and Kolmar AC LP gas powered industrial trucks to load tractor trailers were not provided training in the hazards of closed environments where insufficient ventilation or poor vehicle maintenance could cause a buildup of carbon monoxide.    Observed on or about 6/12/2014.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1200

1910.178 L04 III

Other-than-serious 1 instance 3 exposed
Issued
Aug 4, 2014
Abate by
Sep 19, 2014
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years.    a)  Warehouse    Employees who operate Clark LP gas and Kolmar AC LP gas powered industrial trucks (forklifts) were not evaluated at least every three years to ensure that the operator had the knowledge and skills to operate the powered industrial truck safely to prevent accidents from unsafe operations.      Observed on or about 06/12/2014.
Recent events (2)
  • · I (O) $0
  • · Z (S) $1600

1910.212 A03 II

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 4, 2014
Abate by
Sep 19, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    (a) Warehouse    "Old Sheet Baler(blue)" used to compact and bale cans did not have guards or interlocks to prevent employees from placing their body in the danger zone during the operating cycle.      "Better Baler (EPCO)" used to compact scrap aluminum did not have guards or interlocks to prevent employees from placing their body in the danger zone during the operating cycle.    (b) Wire Stripping area    Wire stripper did not have an appropriate guard to prevent employees from placing their body in the danger zone during the operating cycle.      Condition observed on or about 06/12/2014
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 4, 2014
Abate by
Sep 19, 2014
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Compacting Area/Upstairs    EPCO Baler "Better Baler"  was not maintained in accordance with its electrical equipment listing and labeling, in that the strain relief was damaged and a foot pedal activating device was used as a hand controller.    Observed on or about 06/12/2014.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1600

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 4, 2014
Abate by
Aug 28, 2014
Penalty
Initial $1,600 · Current $920 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.    a)  Retail/Refurbishing area of warehouse      Seven (7) interconnected extension cords were used as a substitute for fixed wiring to provide electricity to products on display for resale exposing employees to an electrical shock.    Observed on or about 6/12/2014.
Recent events (2)
  • · I (S) $920
  • · Z (S) $1600

1910.1025 H01

Serious Gravity 5 1 instance 7 exposed
Issued
Aug 4, 2014
Abate by
Aug 14, 2014
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead.    a) Break/lunch area    A layer of dust on the surface of the lunch table in the break area where employees ate contained 383 micrograms per square foot  (µg/ft2 ) of lead. The current (2012) U.S. Dept. of Housing and Urban Development (HUD) guideline for lead on floors is 40 micrograms per square foot  (µg/ft2 ).      Observed or about 6/12/14.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339804627.