OSHA Inspection: VENTRA BELVIDERE LLC

Fatality or catastrophe inspection · Safety discipline

On , OSHA opened a fatality or catastrophe safety inspection of VENTRA BELVIDERE LLC in 1805 INDUSTRIAL COURT, BELVIDERE, IL 61008 (NAICS 336111). OSHA activity number 339805129.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ventra Belvidere LLC for free Get an email when a new federal OSHA severe-injury report for Ventra Belvidere LLC is published. One employer, no account, unsubscribe in one click.
Site address
1805 INDUSTRIAL COURT
City
BELVIDERE
State
IL
ZIP
61008
Mailing
1805 INDUSTRIAL COURT, BELVIDERE, IL 61008
Inspection type
Fatality or catastrophe (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336111
Employees
106
Ownership type
Private (A)

8 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 6, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  a) On or about June 9, 2014, the automobile bumper/fascia sequencing machine (MK 74 Front Station 2) was not provided with a properly applied presence sensing device. The device failed to prevent operating cycle(s) from continuing after employee(s) passed through the sensing field. Employees were exposed to caught-in and crushing hazards in the point of operation.  b) On or about June 9, 2014, the automobile bumper/fascia sequencing machine (MK-49) Front Station 2) was not provided with a properly applied presence sensing device. The device failed to prevent operating cycle)s) from continuing after employee(s) passed through the sensing field. Employees were exposed to caught-in and crushing hazards in the point of operation.
Recent events (1)
  • · Z (S) $7000

1910.212 A03 II

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 6, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  a) On or about June 8, 2014, the automobile bumper/fascia sequencing machine (MK-84 Front Station 1) was not provided with a properly applied presence sensing device. The device failed to prevent operating cycle(s) from continuing after employee(s) passed through the sensing field. Employees were exposed to caught-in and crushing hazards in the point of operation.  b) On or about June 8, 2014, the automobile bumper/fascia sequencing machine (MK-49 Front Station 1) was not provided with a properly applied presence sensing device. The device failed to prevent operating cycle(s) from continuing after employee(s) passed through the sensing field. Employees were exposed to caught-in and crushing hazards in the point of operation.
Recent events (1)
  • · Z (S) $7000

1910.212 A03 II

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 6, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  a) On or about June 7, 2014, the automobile bumper/fascia sequencing machine (MK 74 Front Station 1) was not provided with a properly applied presence sensing device. The device failed to prevent operating cycle(s) from continuing after employee(s) passed through the sensing field. Employees were exposed to caught-in and crushing hazards in the point of operation.  b) On or about June 7, 2014, the automobile bumper/fascia sequencing machine (MK-49 Front Station 1) was not provided with a properly applied presence sensing device. The device failed to prevent operating cycle(s) from continuing after employee(s) passed through the sensing field. Employees were exposed to caught-in and crushing hazards in the point of operation.
Recent events (1)
  • · Z (S) $7000

1910.147 C04 II

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 10, 2014
Abate by
Jan 14, 2015
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to A through D of this section:     Employees were exposed to electrical shock, crushing and laceration hazards in that the employer did not ensure that lockout/tagout procedures clearly and specifically outlined the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy, including the provisions listed below:     (A)    A specific statement of the intended use of the procedure;    (B)    Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;   (C)    Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and   (D)    Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (3)
  • · F (S) $6300
  • · C (S) $6300
  • · Z (S) $6300

1910.147 C07 I

Serious Gravity 10 1 instance 66 exposed
Issued
Dec 10, 2014
Abate by
Jan 14, 2015
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees:  Employees were exposed to electrical shock, crushing and laceration hazards in that the employer did not ensure that lockout/tagout training was provided to "authorized" and "affected" employees to ensure that the purpose and function of the energy control program were understood by employees and that the knowledge and skills required for the safe application, usage and removal of the energy controls were acquired by employees.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (3)
  • · F (S) $6300
  • · C (S) $6300
  • · Z (S) $6300

1910.212 A03 II

Serious Gravity 10 9 instances 66 exposed
Issued
Dec 10, 2014
Abate by
Jan 14, 2015
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  The following automobile bumper/fascia sequencing machines were not provided with adequately integrated safeguards.  Employees were exposed to caught-in and crushing hazards in the point of operation.  a)    MK 74 Front Station 2  b)    MK 49 Front Station 1  c)    PF 41 Front Station 1  d)    PF 41 Front Station 2  e)    PF 41 Front Station 3  f)    MK 74 Rear Station 1  g)    MK 49 Rear Station 1  h)    MK 49/74 Rear Station 3 (Step Pad)  i)     PF 41 Rear Station 1   Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (3)
  • · F (S) $6300
  • · C (S) $6300
  • · Z (S) $6300

1910.305 G01 IV A

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 10, 2014
Penalty
Initial $4,500 · Current $4,500
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Maintenance Dept.  An extension cord was used in lieu of fixed conduit and run along an interior wall to connect the electrical control panel for the outside sprinkler system to a power outlet.  There is no abatement documentation or certification required for this item.
Recent events (3)
  • · F (S) $4500
  • · C (S) $4500
  • · Z (S) $4500

1910.212 A03 II

Serious Gravity 10 2 instances 66 exposed
Issued
Dec 10, 2014
Abate by
Jan 14, 2015
Penalty
Initial $70,000 · Current $7,000 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.    a)    On or about June 10, 2014, the automobile bumper/fascia sequencing machine (MK 74 Front Station 1) was not provided with a properly applied presence sensing device. The device failed to prevent operating cycle(s) from continuing after employee(s) passed through the sensing field. Employees were exposed to caught-in and crushing hazards in the point of operation.       b)    On or about June 10, 2014, the automobile bumper/fascia sequencing machine (MK-49 Front Station 2) was not provided with a properly applied presence sensing device. The device failed to prevent operating cycle(s) from continuing after employee(s) passed through the sensing field. Employees were exposed to caught-in and crushing hazards in the point of operation.       Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (3)
  • · F (S) $7000
  • · C (W) $70000
  • · Z (W) $70000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339805129.