CORTLAND, NY —
OSHA Inspection: BUILDER'S BEST HOME IMPROVEMENT CENTER INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BUILDER'S BEST HOME IMPROVEMENT CENTER INC. in 3798 LUKER ROAD, CORTLAND, NY 13045 (NAICS 444110). OSHA activity number 339809683.
Where did this inspection happen?
- Establishment
- BUILDER'S BEST HOME IMPROVEMENT CENTER INC.
- Site address
- 3798 LUKER ROAD
- City
- CORTLAND
- State
- NY
- ZIP
- 13045
- Mailing
- 3798 LUKER ROAD, CORTLAND, NY 13045
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444110
- Employees
- 21
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $1620.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent): a) B Bay Shower and toilet mezzanine, on or about 6/18/14: Open sided floors at two wooden gates along the mezzanine, approximately 15 feet from floor level, were not provided with midrails. b) B Bay, Vinyl siding mezzanine, on or about 6/18/14: Open sided floor along the mezzanine, approximately 5 1/2" from floor level, was not provided with midrails. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $1620
- — Z (S) $2700
1910.24 F
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs: a) New Warehouse, loading dock, on or about 6/18/14: A fixed stairway with six risers was not uniform throughout in that five risers measured 7 inches and the bottom riser measured 10 inches. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.24 H
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: a) New Warehouse, loading dock, on or about 6/18/14: A fixed stairway with six risers was not provided with standard stair railings. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $2025.00 · Current $1215.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) At the establishment, on or about 6/18/14: An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years in that the last evaluations conducted were January, 2006. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1215
- — Z (S) $2025
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a) In the yard, on or about 6/18/14: A Hyster forklift #28 did not have an operational horn. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) A Bay, Nail Aisle, on or about 6/18/14: A circuit breaker panel did not have 15 breakers labeled as to what they controlled. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 444110)
TACOMA, WA—2026-07-08
WA317991863 - LOWES HOME CENTERS LLC
HUNTSVILLE, AL—2026-06-30
THE HOME DEPOT U.S.A., INC.
RICHLAND, WA—2026-06-26
WA317991859 - HOME DEPOT INC THE
HENDERSONVILLE, TN—2026-06-26
84 LUMBER
FERNDALE, WA—2026-06-25
WA317991811 - BFS GROUP LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339809683.