Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: BP AMOCO CHEMICAL COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BP AMOCO CHEMICAL COMPANY in 2800 FM 519 E., TEXAS CITY, TX 77590 (NAICS 325199). OSHA activity number 339811879.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BP Amoco Chemical Company — free Get an email when a new federal OSHA severe-injury report for BP Amoco Chemical Company is published. One employer, no account, unsubscribe in one click.
Site address
2800 FM 519 E.
City
TEXAS CITY
State
TX
ZIP
77590
Mailing
P O BOX 1688, TEXAS CITY, TX 77590
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325199
Employees
53
Ownership type
A

3 citations on file for this inspection.

1910.147 D03

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Nov 26, 2014
Abate by
Jan 1, 2015
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).  On or about June 09, 2014, and at prior times, at the BP Amoco Chemical Company in Texas City, TX, the employer did not ensure that all energy isolating devices was capable of isolating all energy sources to T-501 and the spool piece in the RV548 outlet piping, while performing maintenance in the PX1 Unit.
Recent events (3)
  • — R (S) $0
  • — C (S) $5000
  • — Z (S) $5000

1910.147 D05 II

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 26, 2014
Abate by
Jan 1, 2015
Penalty
Initial $0 · Current $5,000
29 CFR 1910.147(d)(5)(ii): If there is a possibility of reaccumulation of stored energy to a hazardous level, the employer shall continue verification of isolation until the servicing or maintenance is completed, or until the possibility of such accumulation no longer exists.    On or about June 09, 2014, and at prior times, at the BP Amoco Chemical Company in Texas City, TX, the employer did not ensure that there was a continued verification of isolation when working on the RV548 outlet piping while performing maintenance on the PX1 Unit.
Recent events (3)
  • — R (S) $5000
  • — C (S) $0
  • — Z (S) $0

1910.147 D06

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Nov 26, 2014
Abate by
Jan 1, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(6): The authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished prior to starting work on machines or equipment that have been locked out or tagged out.  On or about June 09, 2014, and at prior times, at the BP Amoco Chemical Company in Texas City, TX, the employer did not ensure that authorized employees verified that isolation and deenergization had been accomplished in T-501 and the spool piece in the RV548 outlet piping, while performing maintenance in the PX1 Unit.
Recent events (3)
  • — R (S) $0
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339811879.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.