BETHLEHEM, PA ·
OSHA Inspection: MAR-ALLEN CONCRETE PRODUCTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAR-ALLEN CONCRETE PRODUCTS, INC. in 144 SHIMERSVILLE RD., BETHLEHEM, PA 18015 (NAICS 238110). OSHA activity number 339812489.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAR-ALLEN CONCRETE PRODUCTS, INC.
- Site address
- 144 SHIMERSVILLE RD.
- City
- BETHLEHEM
- State
- PA
- ZIP
- 18015
- Mailing
- 490 MILLWAY ROAD, EPHRATA, PA 17522
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 50
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Oct 1, 2014
- Penalty
- Initial $2,023 · Current $1,010 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employer allowed a JLG aerial lift to be used as fall protection anchorage for employees working outside the lift basket creating the potential for the lift to tip over and/or the anchorage points to fail. a) Bethlehem Waste Water Treatment Plant, Digester Tank Dome Top -- On or about June 16, 2014, three employees, whose fall protection systems were anchored to the basket of a JLG aerial lift approximately 25 feet away, were performing roofing modifications to the dome shaped top of a Digester Tank more than six feet above grade. The employees were 1) utilizing the lift as fall protection anchorage which is outside of its design purposes of positioning personnel, their tools and equipment, 2) attaching more than one fall protection anchor to a single anchorage point on the lift, and 3) using the lift in its least stable forward position and not leveled. Among other feasible means of abatement, operators must only use this type of aerial lift as found in the JLG 800A/AJ Operator's Manual under 1) Section 1.3 General, which states, "Do not use the machine for any purpose other than positioning personal, their tools, and equipment", 2) Section 1.3, Trip and Fall Hazards, which states, Attach only one (1) lanyard per lanyard anchorage point, 3) Section 4, Machine Operation, Figure 4-1, which states Machine will upset in this direction if overloaded or operated on an out of level surface.
Recent events (3)
- · F (O) $1010
- · C (S) $2023
- · Z (S) $2023
More inspections at Mar-Allen Concrete Products, INC.
View Mar-Allen Concrete Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339812489.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.