BANGOR, ME ·
OSHA Inspection: AFFILIATED MATERIAL SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AFFILIATED MATERIAL SERVICES in 70 BENNETT STREET, BANGOR, ME 04401 (NAICS 423450). OSHA activity number 339812653.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AFFILIATED MATERIAL SERVICES
- Site address
- 70 BENNETT STREET
- City
- BANGOR
- State
- ME
- ZIP
- 04401
- Mailing
- P. O. BOX 940, BANGOR, ME 04401
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423450
- Employees
- 38
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.242 B
- Issued
- Jul 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Service & Repair Shop - The Craftsman 1 hp. 125 p.s.i. air compressor used to clean out the residue inside sterilizer tubes was not reduced to less than 30 p.s.i.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B02
- Issued
- Jul 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: In the following instances, workstations connected relocatable power taps in a daisy chain series in order to extend electrical power to energize their desk equipment: Office Area - a) Inventory Control, b) Analyst, c) Senior Analyst, d) Item Master Specialist
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.242 A
- Issued
- Jul 1, 2014
- Penalty
- Initial $2,975 · Current $2,529 Reduced
General-duty citation text
29 CFR 1910.242(a): General requirements. Each employer shall be responsible for the safe condition of tools and equipment used by employees, including tools and equipment which may be furnished by employees. Service & Repair Shop - The employer did not inspect the condition of the personal Craftsman 1 hp. 125 p.s.i. air compressor prior to placing it to service at the shop.
Recent events (2)
- · I (O) $2528.75
- · Z (S) $2975
More inspections in this industry (NAICS 423450)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339812653.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.