Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: VINSON GUARD SERVICE, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of VINSON GUARD SERVICE, INC. in 901 CLARK AVE, ALBANY, GA 31705 (NAICS 561612). OSHA activity number 339813065.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vinson Guard Service, INC. for free Get an email when a new federal OSHA severe-injury report for Vinson Guard Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
901 CLARK AVE
City
ALBANY
State
GA
ZIP
31705
Mailing
2031 NORTH SLAPPEY BLVD., #C, ALBANY, GA 31701
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561612
Employees
10
Ownership type
Private (A)

2 citations on file for this inspection.

1910.305 A02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 2, 2014
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners:  a) Guard house, north gate  on or about April 4, 2014, flexible cord was being used on a permanent basis to provide power to the metal gate, resulting in an electrical hazard    ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (1)
  • · Z (S) $1785

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   a) Guard house, north gate  on or about April 4, 2014, the 120-volts electrical junction box had an unused opening on the bottom right side from a missing knockout, exposing employees to electrical shock hazards.     ABATEMENT CERTIFICATION IS NOT REQUIRED