Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: COOKE AQUACULTURE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COOKE AQUACULTURE, INC. in 40 BARREN RD, EASTPORT, ME 04631 (NAICS 112511). OSHA activity number 339815367.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cooke Aquaculture, INC. — free Get an email when a new federal OSHA severe-injury report for Cooke Aquaculture, INC. is published. One employer, no account, unsubscribe in one click.
Site address
40 BARREN RD
City
EASTPORT
State
ME
ZIP
04631
Mailing
P.O. BOX 263, EASTPORT, ME 04631
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
112511
Employees
47
Ownership type
A

3 citations on file for this inspection.

1910.253 B02 IV

Serious Gravity 1 2 instances 4 exposed
Issued
Aug 7, 2014
Abate by
Aug 15, 2014
Penalty
Initial $2,700 · Current $2,700
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:   Maintenance Shop - Valve protection caps were not on the oxygen and fuel-gas cylinders in storage behind the welding table.
Recent events (1)
  • — Z (S) $2700

1910.253 B04 I

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 7, 2014
Abate by
Aug 15, 2014
Penalty
Initial $2,700 · Current $2,700
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders:  Maintenance Shop - An oxygen cylinder and a fuel-gas cylinder were stored beside each other.
Recent events (1)
  • — Z (S) $2700

1910.305 B01 I

Other-than-serious 3 instances 4 exposed
Issued
Aug 7, 2014
Abate by
Aug 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:  Maintenance shop - Three switch boxes had missing knockouts or plugs.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339815367.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.