Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: NATIONAL FOUNDRY AND MFG. INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL FOUNDRY AND MFG. INC. in 299 FOUNDRY RD., CRANE, TX 79731 (NAICS 331513). OSHA activity number 339817736.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Foundry and MFG. INC. for free Get an email when a new federal OSHA severe-injury report for National Foundry and MFG. INC. is published. One employer, no account, unsubscribe in one click.
Site address
299 FOUNDRY RD.
City
CRANE
State
TX
ZIP
79731
Mailing
P. O. BOX 1146, CRANE, TX 79731
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331513
Employees
24
Ownership type
Private (A)

9 citations on file for this inspection.

1910.26 C02 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 10, 2014
Abate by
Dec 20, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.26(c)(2)(vii): Ladders having defects were not marked and taken out of service until repaired by either maintenance department or the manufacturer.    On or about June 17, 2014 the employer did not prevent the use of a damaged ladder to access the sand mixer exposing the employees to fall hazards.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.101 B

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 10, 2014
Abate by
Dec 20, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:      On or about June 17, 2014 the employer did not ensure an argon bottle containing compressed gas was secure exposing employees to struck-by hazards.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 10, 2014
Abate by
Dec 20, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      On or about June 17, 2014 in the shop the employer did not prevent the employees from using a chop saw that had it's safety hood held open by a metallic wire exposing employees to ingoing nip points.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.215 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 10, 2014
Abate by
Dec 20, 2014
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:     On or about June 17, 2014 at the jobsite site employees were exposed to struck-by hazards when the work rest on a bench grinder exceeded 1/8 inch.
Recent events (2)
  • · I (S) $1440
  • · Z (S) $2400

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 10, 2014
Abate by
Dec 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   On or about June 17, 2014 at the jobsite site employees were exposed to struck-by hazards when the tongue guard gap on a bench grinder exceeded 1/4 inch.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 10, 2014
Abate by
Dec 20, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:      On or about June 17, 2014 at the jobsite employees were exposed to electrical shock hazards when the power cord of a fan had been spliced.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.303 B07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 10, 2014
Abate by
Dec 20, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxillary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substanially equivalent to the wall of the equipment:     On or about June 17, 2014 in the oilfield shop employees were exposed to electrical shock hazards when a breaker box was missing a knockout.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.303 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 10, 2014
Abate by
Dec 20, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:      On or about June 17, 2014 on the utility shop's west wall a circuit breaker panel box that had not been properly marked to indicate the systems that each breaker controlled which exposed employees the electrical shock hazards.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 10, 2014
Abate by
Dec 20, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    On or about June 18, 2014 in the shop area employees were exposed to electrical shock hazards when a flexible cable was used to supply power to a 240 volt fan.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

View National Foundry and MFG. INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339817736.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.