FRAZER, PA —
OSHA Inspection: J & L BUILDING MATERIALS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of J & L BUILDING MATERIALS in 600 LANCASTER AVENUE, FRAZER, PA 19355 (NAICS 444190). OSHA activity number 339819575.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & L BUILDING MATERIALS
- Site address
- 600 LANCASTER AVENUE
- City
- FRAZER
- State
- PA
- ZIP
- 19355
- Mailing
- 600 LANCASTER AVENUE, FRAZER, PA 19355
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444190
- Employees
- 44
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.176 B
- Issued
- Oct 6, 2014
- Abate by
- Oct 24, 2014
- Penalty
- Initial $4,500 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a) J & L Building Materials, Inc. - The employer placed wooden pallets of asphalt roofing shingles supported on approximately a four inch steel lip at a height between 4 and 15 feet above ground level. The physical condition of the wooden pallets [e.g. dry rotted and bowing] had destabilized and the weight of the supplies stored upon it has increased the possibility of the materials and pallets collapsing on employees and/or to the ground surface. This was observed on June 26, 2014.
Recent events (2)
- — I (S) $3000
- — Z (S) $4500
1910.22 D01
- Issued
- Oct 6, 2014
- Abate by
- Oct 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent. a) J & L Building Materials - The employer stored heavy equipment and supplies on shelving in warehouse one - door one, which did not have an approved load rating attached to any of its structures. This was observed on June 23, 2014.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 I
- Issued
- Oct 6, 2014
- Abate by
- Nov 28, 2014
- Penalty
- Initial $6,300 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(i): Refresher training, including an evaluation of the effectiveness of that training, was not conducted as required by paragraph (l)(4)(ii) to ensure that the operator has the knowledge and skills needed to operate the powered industrial truck safely. a) J & L Building Materials - The employer did not ensure that their employees who operate the Toyota propane powered industrial trucks were provided refresher training to skillfully use the equipment. This was observed on June 23, 2014.
Recent events (2)
- — I (S) $4000
- — Z (S) $6300
1910.178 N14
- Issued
- Oct 6, 2014
- Abate by
- Oct 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(n)(14): Traveling fork trucks did not avoid running over loose objects on the roadway surface: a) J & L Building Material- Employees were transporting pallets of building materials [e.g. asphalt roof shingles and five gallon buckets of roofing aluminum coating] while operating powered industrial trucks over an uneven surface which ranged in length between four (4) and six (6) square feet. This was observed on June 23, 2014.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 Q07
- Issued
- Oct 6, 2014
- Abate by
- Oct 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: a) J & L Building Materials - The employer did not ensure that an adequate inspection of the propane powered Toyota industrial trucks was conducted prior to being used at the facility. A propane powered industrial truck being used in the warehouse had a horn that was not operational. This was observed on June 23, 2014.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at J & L Building Materials
View J & L Building Materials's full OSHA safety record →
More inspections in this industry (NAICS 444190)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339819575.