CHICAGO, IL —
OSHA Inspection: BROADWAY CONSTRUCTION SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BROADWAY CONSTRUCTION SERVICES, INC. in 6728 S. WESTERN AVENUE, CHICAGO, IL 60636 (NAICS 237110). OSHA activity number 339820532.
Where did this inspection happen?
- Establishment
- BROADWAY CONSTRUCTION SERVICES, INC.
- Site address
- 6728 S. WESTERN AVENUE
- City
- CHICAGO
- State
- IL
- ZIP
- 60636
- Mailing
- 706 W. BUENA STREET, CHICAGO, IL 60613
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1740.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: a) On or about June 24, 2014 - at the jobsite located at 6728 S. Western Avenue, Chicago, IL. - employees performing piping operations in a trench measuring approximately nine (9) feet eight (8) inches in depth, five (5) feet in width, and nine (9) feet in length were using inadequate shoring in the trench, thereby exposing the employees to cave in hazards.
Recent events (2)
- — I (S) $1740
- — Z (S) $2000
1926.652 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.652(g)(2): Additional requirement for shield systems used in trench excavations. Excavations of earth material to a level not greater than 2 feet (.61 m) below the bottom of a shield shall be permitted, but only if the shield is designed to resist the forces calculated for the full depth of the trench, and there are no indications while the trench is open of a possible loss of soil from behind or below the bottom of the shield: a) On or about June 24, 2014 - at the jobsite located at 6728 S. Western Avenue, Chicago, IL. - employees performing piping operations in a trench measuring approximately nine (9) feet eight (8) inches in depth, five (5) feet in width, and nine (9) feet in length were using a trench box which had approximately two (2) and half (1/2) feet of unprotected soil under the (shoring) shield system, thereby exposing the employees to cave in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.652(d)(1): Materials and equipment used for protective systems shall be free from damage or defects that might impair their proper function: a) On or about June 24, 2014 - at the jobsite located at 6728 S. Western Avenue, Chicago, IL. - employees performing piping operations in a trench measuring approximately nine (9) feet eight (8) inches in depth, five (5) feet in width, and nine (9) feet in length were using a trench box which had defective parts, thereby exposing the employees to cave in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support: a) On or about June 24, 2014 - at the jobsite located at 6728 S. Western Avenue, Chicago, IL. - employees performing piping operations in a trench measuring approximately nine (9) feet eight (8) inches in depth, five (5) feet in width, and nine (9) feet in length were using an extendable ladder that was not extended three (3) feet above the upper landing surface of the trench, thereby exposing the employees to fall hazards.
Recent events (2)
- — I (S) $500
- — Z (S) $1200
More inspections at BROADWAY CONSTRUCTION SERVICES, INC.
CHICAGO, IL—2008-09-19 00:00:00
BROADWAY CONSTRUCTION SERVICES, INC.
PALOS HEIGHTS, IL—2003-03-21 00:00:00
BROADWAY CONSTRUCTION SERVICES, INC.
NORTH AURORA, IL—2001-04-02 00:00:00
BROADWAY CONSTRUCTION SERVICES, INC.
CHICAGO, IL—1998-08-19 00:00:00
BROADWAY CONSTRUCTION SERVICES, INC.
View BROADWAY CONSTRUCTION SERVICES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
CHICAGO, IL—2026-07-15
SUSTAINABLE SEWER & WATER INC.
LAKE FOREST, IL—2026-07-15
GREVERS CORPORATION DBA NORTH SHORE BORING
CHEYENNE, WY—2026-07-15
AZTEC CONSTRUCTION
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339820532.