Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: NISSIN BRAKE GEORGIA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NISSIN BRAKE GEORGIA, INC. in 216 THACKER DR, ROCK SPRING, GA 30739 (NAICS 336340). OSHA activity number 339820797.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nissin Brake Georgia, INC. for free Get an email when a new federal OSHA severe-injury report for Nissin Brake Georgia, INC. is published. One employer, no account, unsubscribe in one click.
Site address
216 THACKER DR
City
ROCK SPRING
State
GA
ZIP
30739
Mailing
216 THACKER DR, ROCK SPRING, GA 30739
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336340
Employees
9000
Ownership type
Private (A)

10 citations on file for this inspection.

1910.147 D03

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Nov 13, 2014
Abate by
Dec 10, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:  a.  Heat Treat #2 - The employees adjusting the machinery and  bypassing the guards on the heat treat conveyor area were not protected by machinery isolation of the equipment prior to starting work.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.217 D06 I

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Dec 10, 2014
Penalty
Initial $3,000 · Current $1,200 Reduced
29 CFR 1910.217(d)(6)(i): Tonnage and stroke requirements were neither stamped on die(s) nor recorded on records readily available to the die setter:    a.  Press Room - The dies in storage and used on the mechanical power press were not marked or recorded on records.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $3000

1910.217 D09 III

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Dec 10, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.217(d)(9)(iii): The employer did not provide die stops or other means to prevent losing control of the die while setting or removing dies on mechanical power press(es) which were are inclined:   a.  Mechanical Power Press - The employer did not provide die stops when the employees changed and removed the dies.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.219 C02

Other-than-serious 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Dec 10, 2014
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.219(c)(2): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, were not protected by a stationary casing enclosing shafting completely:    a.  Caliper Assembly Clean Room - The horizontal shaft on the piston seal conveyor was not covered or guarded.
Recent events (2)
  • · I (O) $2500
  • · Z (S) $5000

1910.219 C04 I

Deleted Serious Gravity 10 8 instances 1 exposed
Issued
Nov 13, 2014
Abate by
Dec 10, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  a.  Caliper Bracket Machine Conveyors - The 2 conveyors used in the area did not have all 8 their shaft ends either covered or guarded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.303 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 13, 2014
Abate by
Dec 10, 2014
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:     a.  Electrical Room - All branch circuits and panels were not marked as to their purpose.
Recent events (2)
  • · I (S) $3500
  • · Z (S) $5000

1910.332 B01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 13, 2014
Abate by
Dec 10, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  a.  Worksite - The employees had not been trained in and were not familiar with safety related work practices necessary for protection from hazards associated with shock and arc flash/blast hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.335 A01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 13, 2014
Abate by
Dec 10, 2014
Penalty
Initial $7,000 · Current $5,000 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    (a)  Worksite - The employees who worked on electrical equipment over 50 volts were not provided with the appropriate personal protective equipment suitable for the hazards associated with arc flash/blast.
Recent events (2)
  • · I (S) $5000
  • · Z (S) $7000

1910.335 A01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 13, 2014
Abate by
Dec 10, 2014
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.335(a)(1)(ii): Protective equipment was not maintained in a safe, reliable condition and/or was not periodically inspected or tested:    a.  Maintenance area - The 2 pairs of Salisbury electrical protective work gloves used by the maintenance employees had not been periodically tested or inspected as required thereby exposing the employees to shock hazards.    ABATEMENT NOTE:  Electrical protective equipment needs to be subjected to periodic electrical tests in accordance with 1910.137 Tables I-5 and I-6.
Recent events (2)
  • · I (S) $0
  • · Z (S) $5000

1910.303 G01 II

Other-than-serious 1 instance 1 exposed
Issued
Nov 13, 2014
Abate by
Dec 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   a.  Electrical Room - The required workspace in front of electrical panels was not kept free and clear of materials storage.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Nissin Brake Georgia, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339820797.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.