HOUSTON, TX ·
OSHA Inspection: DIMENSIONAL MACHINE WORKS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIMENSIONAL MACHINE WORKS LLC in 6930 SAN ANTONIO RD, HOUSTON, TX 77040 (NAICS 332999). OSHA activity number 339821381.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIMENSIONAL MACHINE WORKS LLC
- Site address
- 6930 SAN ANTONIO RD
- City
- HOUSTON
- State
- TX
- ZIP
- 77040
- Mailing
- 6930 SAN ANTONIO RD, HOUSTON, TX 77040
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 37
- Ownership type
- A
Citations
13 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
OSH ACT of 1970 Section (5) (a) (1): Section 5(a) (1) of the Occupational Safety and Health Act of 1970: The employer does not furnish to each of his employees employment and a place of employment which are free from the recognized hazards of being caught-in, which are causing or likely to cause death or serious physical harm to employees. a. This violation was observed on or about June 24, 2014, when employees at workstation TAKISAWA TC-3 were exposed to caught-in hazards while working or cleaning metal shavings on and around the rotating part of a chip conveyor without a guarded. b. This violation was observed on or about June 24, 2014, when employees at workstation MORI SEIKI SL-15 were exposed to caught-in hazards while working or cleaning metal shavings on and around the rotating part of a chip conveyor without a guard. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation describing the actions it is taking to ensure that employees are not exposed to caught-in hazards.
Recent events (2)
- · I (S) $1925
- · Z (S) $3850
1910.215 A02
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: The employer does not ensure that the spindle, nut, and flange on bench grinders are covered with the side guards to prevent employee injury. This violation was observed on or about June 24, 2014 at the North wall of the manufacturing area where employees were exposed to struck-by hazards when operating a bench grinder without the side guard. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all bench grinder are equipped with the side guards.
Recent events (2)
- · I (S) $1925
- · Z (S) $3850
1910.219 F03
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: The employer does not guard all sprocket wheels and chains that are located 7 feet or less above floors of machines whose operation exposed employees to injury. This violation was observed on or about June 24, 2014, in the manufacturing area where employees were exposed to caught-by hazards when working near and walking by a motor driven chain and sprocket assembly without a guard enclosing the chain and sprocket. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that guards are installed on chains and sprockets.
Recent events (2)
- · I (S) $1925
- · Z (S) $3850
1910.147 C01
- Issued
- Aug 4, 2014
- Abate by
- Sep 17, 2014
- Penalty
- Initial $10,780 · Current $5,390 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. The employer does not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment is isolated from the energy source and rendered inoperative. a. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a TAKISAWA TC-1 serial number THZX0841 without an established program consisting of energy control procedures, employee training and periodic inspections. b. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI SL-15 serial number 1612 without an established program consisting of energy control procedures, employee training and periodic inspections. c. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a KINGSTON HL1500 serial number C8700615A without an established program consisting of energy control procedures, employee training and periodic inspections. d. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a TAKISAWA LX-106 serial number C9906034-034 without an established program consisting of energy control procedures, employee training and periodic inspections. e. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a TAKISAWA TC-3 serial number THUAR-2804 without an established program consisting of energy control procedures, employee training and periodic inspections. f. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a TAKISAWA TC-20 serial number TLMX 81641 without an established program consisting of energy control procedures, employee training and periodic inspections. g. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a TAKISAWA TC-4 serial number THZX 1275 without an established program consisting of energy control procedures, employee training and periodic inspections. h. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a YAMA SEIKI GA-330L serial number 88A060 without an established program consisting of energy control procedures, employee training and periodic inspections. i. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI SL-200 serial number 134 without an established program consisting of energy control procedures, employee training and periodic inspections. j. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a TAKISAWA EX-110 330L serial number CA12E10270 without an established program consisting of energy control procedures, employee training and periodic inspections. k. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI SL-25MC5 serial number 82 without an established program consisting of energy control procedures, employee training and periodic inspections. l. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI SKL-250B serial number 863 without an established program consisting of energy control procedures, employee training and periodic inspections. m. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI SL-25B serial number 6965 without an established program consisting of energy control procedures, employee training and periodic inspections. n. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI SL-25B serial number 6695 without an established program consisting of energy control procedures, employee training and periodic inspections. o. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a TAKISAWA NLX-110 serial number CM01N10542 without an established program consisting of energy control procedures, employee training and periodic inspections. p. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI SL-25B serial number 6916 without an established program consisting of energy control procedures, employee training and periodic inspections. q. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a PUMA 400B serial number PM350596 without an established program consisting of energy control procedures, employee training and periodic inspections. r. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a PUMA 300LC serial number P25L0290 without an established program consisting of energy control procedures, employee training and periodic inspections. s. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI MH-40 serial number 890 without an established program consisting of energy control procedures, employee training and periodic inspections. t. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a OKK VM7 III serial number 715 without an established program consisting of energy control procedures, employee training and periodic inspections. u. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a KURAKI KV-1000 serial number T01-6509 without an established program consisting of energy control procedures, employee training and periodic inspections. v. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a DOOSAN MV3016L serial number NM4100840 without an established program consisting of energy control procedures, employee training and periodic inspections. w. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a KURAKI KV-700 serial number 8423 without an established program consisting of energy control procedures, employee training and periodic inspections. x. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a KURAKI KV-700 serial number 10227 without an established program consisting of energy control procedures, employee training and periodic inspections. y. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI MV-40B serial number 3410 without an established program consisting of energy control procedures, employee training and periodic inspections. z. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a YAMA SEIKI VMB-1200 serial number 5046 without an established program consisting of energy control procedures, employee training and periodic inspections. aa. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a DOOSAN MV3016LD serial number NM4100824 without an established program consisting of energy control procedures, employee training and periodic inspections. bb. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI MV-40E serial number 980 without an established program consisting of energy control procedures, employee training and periodic inspections. cc. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a DAEWOO DMV-500 serial number AV5S0645 without an established program consisting of energy control procedures, employee training and periodic inspections. dd. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a YAMA SEIKI VMB-1100 serial number 212 without an established program consisting of energy control procedures, employee training and periodic inspections. ee. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a YAMA SEIKI VMB-1100 serial number 4066 without an established program consisting of energy control procedures, employee training and periodic inspections. ff. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a OKK VM5 III serial number 2543 without an established program consisting of energy control procedures, employee training and periodic inspections. gg. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a OKK VM-76R serial number 208 without an established program consisting of energy control procedures, employee training and periodic inspections. hh. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a MORI SEIKI NV5000 serial number NV501EE2851 without an established program consisting of energy control procedures, employee training and periodic inspections. ii. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a OKK MCV560 serial number 116 without an established program consisting of energy control procedures, employee training and periodic inspections. jj. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a OKK MCV460 serial number 129 without an established program consisting of energy control procedures, employee training and periodic inspections. kk. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a OKK PCV55 serial number 498 without an established program consisting of energy control procedures, employee training and periodic inspections. ll. This violation was observed on or about June 24 2014, in the shop area where employees were exposed to struck-by, caught-in, and electrical hazards when performing service and/or maintenance including setting up on a OKK VM5-2 serial number 1352 without an established program consisting of energy control procedures, employee training and periodic inspections. The Dimensional Machine Works, LLC was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.147(c)(1), which was contained in OSHA inspection number 313890493 Citation Number 1, Item Number 1 and was affirmed as a final order on 1/29/2010, with respect to a workplace located at 6930 San Antonio St, Houston, Texas 77040. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that an energy control procedures, training and periodic inspections including specific procedures are developed, documented and implemented to perform lockout/tagout on equipment with multiple sources of energy such as electrical, hydraulic, pneumatic and mechanical energy, before performing maintenance, servicing, and/or setup.
Recent events (2)
- · I (R) $5390
- · Z (R) $10780
1910.212 A01
- Issued
- Aug 4, 2014
- Abate by
- Sep 17, 2014
- Penalty
- Initial $10,780 · Current $5,390 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. The employer does not guard the rotating parts of machines whose operation exposes employees to injury. a. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a TAKISAWA TC-1 serial number THZX0841 without a door interlock. b. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a MORI SEIKI SL-15 serial number 1612 without a functioning door interlock and without the right side cover installed. c This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a TAKISAWA LX-106 serial number C9906034-034 without a functioning door interlock. d. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a TAKISAWA TC-3 serial number THUAR-2804 without a functioning door interlock. e. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a TAKISAWA TC-20 serial number TLMX 81641 without a door interlock. f. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a TAKISAWA TC-4 serial number THZX 1275 without a door interlock and without the side cover of the spindle. g. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a YAMA SEIKI GA-330L serial number 88A060 without a door interlock. h. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a MORI SEIKI SL-200 serial number 134 without a functioning door interlock and without the side cover for the spindle. i. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a TAKISAWA EX-110 serial number: CA12E10270 without a functioning door interlock and without the side cover for the spindle. j. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a MORI SEIKI SL-25MC5 serial number 82 without a door interlock. k. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a MORI SEIKI SKL-250B serial number 863 without a functioning door interlock and without the side cover for the spindle. l. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a MORI SEIKI SL-25B serial number 6965 without a functioning door interlock and without the right side cover exposing the chuck. m. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a MORI SEIKI SL-25B serial number 6695 without a functioning door interlock. n. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a TAKISAWA NLX-110 serial number CM01N10542 without a functioning door interlock. o. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a PUMA 400B serial number: PM350596 without a door interlock and without the whole right side cover exposing the chuck. p. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a PUMA 300LC serial number: P25L0290 without a door interlock and without the side cover for the spindle. q. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a MORI SEIKI MH-40 serial number 890 without a door interlock and without the whole side cover exposing the chuck. r. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a KURAKI KV-1000 serial number T01-6509 without a door interlock. s. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a DOOSAN MV3016L with serial number NM4100840 without a functioning door interlock. t. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a KURAKI KV-700 serial number: 8423 without a door interlock. u. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a KURAKI KV-700 serial number: 10227 without a door interlock. v. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a MORI SEIKI MV-40B serial number 3410 without a door interlock. w. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a YAMA SEIKI VMB-1200 serial number 5046 without a functioning door interlock. x. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a DOOSAN MV3016LD serial number NM4100824 without a functioning door interlock. y. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a MORI SEIKI MV-40E serial number 980 without a door interlock. z. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a DAEWOO DMV-500 serial number AV5S0645 without a door interlock. aa. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a YAMA SEIKI VMB-1100 serial number 212 without a door interlock. bb. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a YAMA SEIKI VMB-1100 serial number 4066 without a door interlock. cc. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating an OKK VM5 III serial number 2543 without a door interlock. dd. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a MORI SEIKI NV5000 serial number NV501EE2851 with a door interlock. ee. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating an OKKMCV560 serial number 116 without a door interlock. ff. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating an OKK MCV460 serial number: 129 without a door interlock. gg. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating an OKK PCV55 serial number 498 without a door interlock. hh. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating an OKK VM5-2 serial number 1352 without a door interlock. ii. This violation was observed on or about June 24, 2014, at the facility where employees were exposed to struck-by and caught-by hazards when operating a KINGSTON HL-1500 serial number C87006154 without a chuck guard. The Dimensional Machine Works, LLC was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 313890493 Citation Number 1, Item Number 2 and was affirmed as a final order on 1/29/2010, with respect to a workplace located at 6930 San Antonio St, Houston, Texas 77040. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all machines that have exposed rotating parts are guarded.
Recent events (2)
- · I (R) $5390
- · Z (R) $10780
1910.215 A04
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $7,700 · Current $3,850 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work. The employer does not ensure that the work rests on bench grinders are adjusted with a maximum opening of one-eighth inch. This violation was observed on or about June 24, 2014 at the North wall of the manufacturing area where employees were exposed to caught in and struck-by hazards when operating a bench grinder without the work rests adjusted to the wheel with a maximum opening of one-eighth inch. The Dimensional Machine Works, LLC was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.215(a)(4), which was contained in OSHA inspection number 313890493 Citation Number 1, Item Number 3 and was affirmed as a final order on 1/29/2010, with respect to a workplace located at 6930 San Antonio St, Houston, Texas 77040. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all bench grinder are equipped with work rests and that they are properly adjusted.
Recent events (2)
- · I (R) $3850
- · Z (R) $7700
1910.215 B09
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. The employer does not ensure that the tongue guards on bench grinders are adjusted with a maximum opening of one-fourth inch. This violation was observed on or about June 24, 2014 at the North west side of the mill area where employees were exposed to struck-by hazards when operating a bench grinder without the tongue guards adjusted properly. The Dimensional Machine Works, LLC was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.215(b)(9), which was contained in OSHA inspection number 313890493 Citation Number 1, Item Number 4 and was affirmed as a final order on 1/29/2010, with respect to a workplace located at 6930 San Antonio St, Houston, Texas 77040. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all bench grinders have their tongue guards adjusted to the grinding wheel with a maximum opening of 1/4th inch.
Recent events (2)
- · I (R) $0
- · Z (R) $0
1910.242 B
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $7,700 · Current $3,850 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. The employer does not ensure that compressed air used for cleaning is reduced to less than 30 psi. This violation was observed on or about June 24, 2014, when employees throughout the facility were exposed to struck-by hazards while blowing off equipment with compressed air without reducing the pressure to 30 p.s.i. The Dimensional Machine Works, LLC was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.242(b) which was contained in OSHA inspection number 313890493 Citation Number 1, Item Number 6 and was affirmed as a final order on 1/29/2010, with respect to a workplace located at 6930 San Antonio St, Houston, Texas 77040. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all compressed air used by employees to blow off equipment is reduced to less than 30 p.s.i.
Recent events (2)
- · I (R) $3850
- · Z (R) $7700
1910.1200 E01
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $4,620 · Current $2,310 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met. The employer has not developed or implemented a written hazard communication program that describes how they comply with this standard regarding labels and other forms of warning, material safety data sheets, and employee information and training. This violation occurred on or about June 24, 2014, and at times prior thereto, where employees were exposed to inhalation and contact hazard while they were required to handle hazardous chemicals such as but not limited to DW40, Hydraulic oil, lubricants, EEZ FOAMY cutting fluid and other chemicals without a written hazard communication program had been developed and implemented. The Dimensional Machine Works, LLC was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.1200(e)(1), which was contained in OSHA inspection number 313890493 Citation Number 1, Item Number 7 and was affirmed as a final order on 1/29/2010, with respect to a workplace located at 6930 San Antonio St, Houston, Texas 77040. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that a written hazard communication program is developed, implemented, and maintained that includes the criteria specified in 29 CFR 1910.1200(f-h).
Recent events (2)
- · I (R) $2310
- · Z (R) $4620
1910.1200 G08
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $4,620 · Current $2,310 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s). The employer does not maintain and make readily accessible copies of safety data sheets for each hazardous chemical in the workplace. This violation occurred on or about June 24, 2014, at the manufacturing area, where employees were exposed to inhalation and skin hazard while using chemicals such as, but not limited to, DW40, Hydraulic oil, lubricants, EEZ FOAMY cutting fluid and other chemicals, the safety data sheet for these chemicals were not maintained at the worksite. The Dimensional Machine Works, LLC was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.1200(g)(1), which was contained in OSHA inspection number 313890493 Citation Number 1, Item Number 8 and was affirmed as a final order on 1/29/2010, with respect to a workplace located at 6930 San Antonio St, Houston, Texas 77040. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that safety data sheets are maintained and made available to employees on all work shifts for all hazardous chemicals in the workplace.
Recent events (2)
- · I (R) $2310
- · Z (R) $4620
1910.178 L02 II
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. The employer does not ensure that employees required to operate forklifts are trained and evaluated. This violation occurred on or about June 24, 2014, and at times prior thereto, when employees in the facility were required to operate forklifts to move material without being trained and evaluated. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that they provide the employees training consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 F06
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section. The employer does not ensure that all chemicals in the workplace are labeled, tagged, or marked with the identity and hazard warning of those chemicals. This violation occurred on or about June 24, 2014, in the manufacturing area where chemicals in portable containers were used without a label or markings as to the chemicals identity or hazard warnings. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all chemical containers in the workplace are labeled with the identity and appropriate hazard warnings of the chemicals therein.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 H03
- Issued
- Aug 4, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv). The employer does not provide the update training according with the revised Hazard Communication Standard. This violation occurred on or about June 24, 2014, and at times prior thereto, when employees in the facility were required to handle hazardous chemicals such as but not limited to DW40, Hydraulic oil, lubricants, EEZ FOAMY cutting fluid and other chemicals without being trained on how to identify the hazard associate to those chemicals according with the revised Hazard Communication Standard. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all employees are trained on all hazards in their work area according with the revised Hazard Communication Standard.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Dimensional Machine Works LLC
View Dimensional Machine Works LLC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339821381.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.