OSHA Inspection: MEDCO, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MEDCO, INC. in 55 E. BRADROCK DRIVE, DES PLAINES, IL 60018 (NAICS 332710). OSHA activity number 339822397.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Medco, INC. — free Get an email when a new federal OSHA severe-injury report for Medco, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MEDCO, INC.
Site address
55 E. BRADROCK DRIVE
City
DES PLAINES
State
IL
ZIP
60018
Mailing
55 E. BRADROCK DRIVE, DES PLAINES, IL 60018
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
13
Ownership type
A

8 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 13, 2014
Abate by
Sep 30, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:     a) Facility Wide - The employer failed to establish a program (lockout/tag out) to control hazardous energy that included energy control procedures for employees to follow, employee training, and periodic inspections to protect employees performing set up and maintenance/servicing on equipment such as the band saws, manual lathes, CNC lathes/turning centers, and similar equipment from injury caused by unexpected start up and energy releases.     In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 13, 2014
Abate by
Sep 30, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):     a) Facility Wide - The employer did not ensure that each powered industrial truck operator was competent to operate the sit down powered industrial truck safely as demonstrated by the successful completion of training and evaluation.    In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.212 A01

Serious Gravity 5 4 instances 6 exposed
Issued
Aug 13, 2014
Abate by
Sep 30, 2014
Penalty
Initial $2,000 · Current $900 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) CNC Turning Area - The sliding barrier doors on the CHNC Hardinge Chuckers, Mori Seiki CNC SL4 turning centers, Yang ML55A turning center, and SL-20 Haas turning center did not protect the operator and other employees in the machine area from hazards such as those created by point of operation, ejected, moving, and rotating parts. The machines were not provided with machine guarding protection such as interlock devices allowing the sliding barrier doors to be opened and the machines to continue operating.     In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $900
  • — Z (S) $2000

1910.215 A04

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 13, 2014
Abate by
Sep 2, 2014
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    a) Shop Area - The work rest on the Stanley pedestal grinder (s/n - G65648A) was not adjusted closely to the wheel with a maximum opening of one-eighth of an inch.  The Stanley grinder had an opening of about four-eighths of an inch.    b) Shop Area - The work rest on the Baldor pedestal grinder (s/n -G8-165-11) was not adjusted closely to the wheel with a maximum opening of one-eighth of an inch.  The Baldor grinder had an opening of about seven-eighths of an inch.      In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.215 B09

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 13, 2014
Abate by
Sep 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a) Shop Area - The Stanley pedestal grinder (s/n - G65648A) did not have an adjustable tongue guard and had a distance of about one inch between the abrasive wheel periphery and the safety guard peripheral.  b) Shop Area - The Baldor pedestal grinder (s/n -G8-165-11) did not have an adjustable tongue guard and had a distance of about one and one-half inch between the abrasive wheel periphery and the safety guard peripheral.  In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2014
Abate by
Sep 2, 2014
Penalty
Initial $2,000 · Current $900 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    a) Lathe Area - The Trak TRL 1745P horizontal lathe had exposed horizontal shafting that was not protected by a stationary casing enclosing the shafting completely or troughs enclosing the sides and top or sides and bottom of the shafting.    In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $900
  • — Z (S) $2000

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2014
Abate by
Sep 2, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded.    a) Lathe Area - The Trak TRL 1745P horizontal lathe had pulley(s) with part(s) seven feet or less from the floor that were not guarded.     In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.219 E03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2014
Abate by
Sep 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)  a) Lathe Area - The Trak TRL 1745P horizontal lathe had vertical belt(s) that were not enclosed by guard(s).   In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Medco, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339822397.