Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LLOYD ROOFING & SIDING, LLC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of LLOYD ROOFING & SIDING, LLC in BRIDGE & WHEATLAND STREETS, PHOENIXVILLE, PA 19460 (NAICS 238170). OSHA activity number 339823668.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lloyd Roofing & Siding, LLC — free Get an email when a new federal OSHA severe-injury report for Lloyd Roofing & Siding, LLC is published. One employer, no account, unsubscribe in one click.
Site address
BRIDGE & WHEATLAND STREETS
City
PHOENIXVILLE
State
PA
ZIP
19460
Mailing
300 KING ROAD, HONEY BROOK, PA 19344
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 4, 2014
Abate by
Aug 8, 2014
Penalty
Initial $2,000 · Current $1,750 Reduced
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.    a) Bridge & Wheatland Sts. Phoenixville, PA - Employees engaged in the complete replacement of a flat roof were not protected from falling by any type of fall protection system.  The approximate fall distance was 27 feet to the ground.     Observed 6/25/2014
Recent events (2)
  • — I (S) $1750
  • — Z (S) $2000

1926.503 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 4, 2014
Abate by
Dec 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): Employer did not provide fall protection training to those employees who might be exposed to a fall hazard.    a) Lloyd Roofing & Siding, LLC - The employer did not provide training to those employees who were exposed to a fall hazard of approximately 27 feet to the ground while performing a complete replacement of a roof.      Observed 6/25/2014
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 4, 2014
Penalty
Initial $2,000 · Current $1,250 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    a) Bridge & Wheatland Sts., Phoenixville, PA - The ladder side rails on the portable metal ladder used to gain access to the roof did not extend at least 3 feet above the roof surface.    b) Bridge & Wheatland Sts., Phoenixville, PA - The ladder side rails on the portable metal ladder used to gain access to the roof porch did not extend at least 3 feet above the roof surface.      Observed 6/25/2014
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2000

1926.1053 B06

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 4, 2014
Abate by
Aug 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(6): Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.  a) Bridge & Wheatland Sts., Phoenixville, PA - The metal extension ladder used to access the roof porch was not secured to prevent accidental displacement when used on ground which was not stable.  Observed 6/25/2014
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339823668.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.