Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: GOZZER CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GOZZER CORPORATION in 79-25 WINCHESTER BOULEVARD, QUEENS VILLAGE, NY 11427 (NAICS 236220). OSHA activity number 339824260.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gozzer Corporation for free Get an email when a new federal OSHA severe-injury report for Gozzer Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
GOZZER CORPORATION
Site address
79-25 WINCHESTER BOULEVARD
City
QUEENS VILLAGE
State
NY
ZIP
11427
Mailing
1043 BROADWAY, ALBANY, NY 12204
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 23, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    A.) On or about Wednesday, May 28, 2014 at 79-25 Winchester Boulevard, Queens Village, NY 11427    A temporary power strip labeled as for "Indoor Use Only" was observed improperly used on the outdoors to power portable tools exposing employees to electrical hazards.    ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  A.) On or about Wednesday, May 28, 2014 at   An extension cord used by employees to power electrical hand tools was observed missing a grounding pin.  ABATEMENT CERTIFICATION IS NOT REQUIRED