DURANT, OK ·
OSHA Inspection: EAGLE SUSPENSIONS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EAGLE SUSPENSIONS in 1811 W. ARKANSAS, DURANT, OK 74701 (NAICS 332611). OSHA activity number 339825820.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAGLE SUSPENSIONS
- Site address
- 1811 W. ARKANSAS
- City
- DURANT
- State
- OK
- ZIP
- 74701
- Mailing
- 1811 W. ARKANSAS, DURANT, OK 74701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332611
- Employees
- 165
- Ownership type
- Private (A)
Citations
11 citations on file for this inspection.
1910.110 H06 II B
- Issued
- Aug 15, 2014
- Abate by
- Sep 30, 2014
- Penalty
- Initial $3,060 · Current $1,836 Reduced
General-duty citation text
29 CFR 1910.110(h)(6)(ii)(b): Containers were not protected by crash rails or guards to prevent physical damage and they were not protected by virtue of their location: On or about June 24, 2014, or at times prior thereto, at the propane tank storage area employees were observed driving propane operated forklift trucks into the areas to refill where there was no crash rails or guards provided around the propane storage tank. Employees were exposed to fire and explosion hazards.
Recent events (2)
- · I (S) $1836
- · Z (S) $3060
1910.179 I
- Issued
- Aug 15, 2014
- Abate by
- Sep 30, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.179(i): Crane(s) equipped with a power traveling mechanism were not provided with a gong or other effective warning signal: On or about June 26, 2014, and at times prior to, in the crane bay area an overhead crane was operated by a remote control device to lift heavy steel parts was not provided with the means (audible alarm or strobe light) to warn employees working in the areas when the cranes were on the move. Employees were exposed to struck-by hazards.
Recent events (2)
- · I (S) $1377
- · Z (S) $2295
1910.212 A01
- Issued
- Aug 15, 2014
- Abate by
- Sep 30, 2014
- Penalty
- Initial $3,825 · Current $2,295 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about June 24, 2014, and at times prior thereto, employees were allowed to operate machines that were found not having proper guards provided, including but not limited to the following instances: 1) At the small shear area, a small shear being operated via a foot pedal. There was a machine guard provided however the openings were big that could allow a hand to enter the point-of-operation. 2) In the machine shop are, a horizontal band saw being operated without blade guard provided to protect employees from contacting the unused portion of the blade while in operation. 3) In the shipping area, a trash compactor being operated without a dead man switch or an interlock gate provided to prevent employees entering the trash compactor while in operation. Employees were exposed to possible amputation and crushing hazards.
Recent events (2)
- · I (S) $2295
- · Z (S) $3825
1910.215 A04
- Issued
- Aug 15, 2014
- Abate by
- Aug 25, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: On or about June 24, 2014, and at times prior thereto, in the machine shop and cold punch areas employees were operating abrasive wheel grinding machines that either did not have work rest provided or the opening between the work rest and the wheel was greater than one-eight inch. Employees were exposed to flying fragments in the event of an exploding wheel.
Recent events (2)
- · I (S) $1377
- · Z (S) $2295
1910.215 B09
- Issued
- Aug 15, 2014
- Abate by
- Aug 25, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about June 24, 2014, and at times prior thereto, in the machine shop and cold punch areas the employer allowed employees operating abrasive wheel grinding machines that either did not have a tongue guard provided or the opening between the tongue guard and the wheel greater one-forth inch. Employees were exposed to flying fragments in the event of an exploding wheel.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.215 D03
- Issued
- Aug 15, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(d)(3): The contact surface(s) of wheel(s), blotter(s) or flange(s) on grinding machine(s) were not flat and free or foreign matter: On or about June 24, 2014, and at times prior thereto, in the machine shop area employer allowed employees to operate abrasive wheel grinding machines that had the abrasive wheels unevenly worn. The employees were exposed to flying fragments in the event of exploding wheels.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.243 C03
- Issued
- Aug 15, 2014
- Abate by
- Aug 25, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel: On or about June 24, 2014 and at times prior thereto, in the Clip area a portable right angle grinder being was used without a safety guard provided. The employee was exposed to hazards of contacting the wheel.
Recent events (2)
- · I (S) $1377
- · Z (S) $2295
1910.252 A02 VII
- Issued
- Aug 15, 2014
- Abate by
- Aug 19, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.252(a)(2)(vii): Where practicable, combustible materials were not relocated at least 35 feet (10.7 m) from the cutting or welding operation work site: On or about June 25, 2014, or at times prior thereto, at the bolt cutting area in the stock room an employee was cutting metal bolts creating sparks while there were combustible materials such as but not limited to cardboard boxes next to the cutting area. Employees were exposed to fire hazards.
Recent events (2)
- · I (S) $1377
- · Z (S) $2295
1910.303 B02
- Issued
- Aug 15, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about June 25, 2014, and at times prior thereto, in the machine shop and stock room areas relocatable power taps (RPT) were observed being used not in accordance with the listed instructions, in that high current consumption equipment was plugged into it. Employees were exposed to possible fire hazards.
Recent events (2)
- · I (S) $1377
- · Z (S) $2295
1910.305 G01 III
- Issued
- Aug 15, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph: On or about June 25, 2014, and at times prior thereto, in the shipping area a flexible electrical cord was observed run through a doorway exposing the flexible cord to damage. This exposed employees to fire and electrical hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.22 D01
- Issued
- Aug 15, 2014
- Abate by
- Sep 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: On or about June 25, 2014, or at times prior thereto, at the storage area above the break room was used for storage purpose did not have floor loading signs posted in a conspicuous place to prevent overloading.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 332611)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339825820.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.