Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE INTEC GROUP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE INTEC GROUP, INC. in 666 SOUTH VERMONT STREET, PALATINE, IL 60067 (NAICS 326199). OSHA activity number 339826919.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Intec Group, INC. — free Get an email when a new federal OSHA severe-injury report for The Intec Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
666 SOUTH VERMONT STREET
City
PALATINE
State
IL
ZIP
60067
Mailing
666 SOUTH VERMONT STREET, PALATINE, IL 60067
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
150
Ownership type
A

6 citations on file for this inspection.

1910.178 L02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 21, 2014
Abate by
Aug 14, 2014
Penalty
Initial $3,060 · Current $2,142 Reduced
29 CFR 1910.178(l)(2)(ii): Training did not consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace:  a) The employer had employees perform partial exercise and employer did not evaluate performance in the work place.
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3060

1910.178 L06

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 21, 2014
Abate by
Aug 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:  a) The employer failed to certify that each operator had been trained and evaluated by maintaining records that included the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation for the forklifts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 5 8 instances 6 exposed
Issued
Jul 21, 2014
Abate by
Jul 31, 2014
Penalty
Initial $3,060 · Current $2,142 Reduced
29 CFR 1910.304(g)(5):  The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:      a) Injection Molding Department - There were eight portable hand lamps with metal shells placed above the machines that did not have a ground pin.
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3060

1910.305 J01 II

Serious Gravity 5 18 instances 6 exposed
Issued
Jul 21, 2014
Abate by
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(1)(ii): Portable hand-lamps supplied through flexible cords were not equipped with a handle of molded composition or other material approved for the purpose, and a substantial guard attached to the lamp-holder or the handle:       a) Injection Molding Department - Attached to the top of the machines to provide better lighting there was 18 portable hand lamps with a metal shell, non-insulated handles, and without a guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
Jul 21, 2014
Abate by
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): The employer had portable fire extinguishers that were not mounted, located, identified and readily accessible to employees without subjecting the employees to possible injury:      a) Technical Manager's Office - The ABC fire extinguisher was blocked by a file rack that was placed directly in front of the fire extinguisher and not readily accessible.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 2 instances 3 exposed
Issued
Jul 21, 2014
Abate by
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): Working space about electrical equipment rated 600 volts, nominal, or was used for storage:  a) Technical Manager Office - A tool box and books were placed directly in front of an electrical cabinet and other disconnect switches.     b) Cooling Tower Area - A plastic drum and conveyor equipment was placed directly in front of an electrical cabinet and other disconnect switches.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View The Intec Group, INC.'s full OSHA safety record →