Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: FLORIDA CONTRACTING SPECIALIST, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FLORIDA CONTRACTING SPECIALIST, INC. in 1463 U.S. 1, FORT PIERCE, FL 34950 (NAICS 238160). OSHA activity number 339827644.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Florida Contracting Specialist, INC. for free Get an email when a new federal OSHA severe-injury report for Florida Contracting Specialist, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1463 U.S. 1
City
FORT PIERCE
State
FL
ZIP
34950
Mailing
214 SW STARFLOWER AVE, PORT SAINT LUCIE, FL 34984
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

7 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 18, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    a)  On or about June 16, 2014, at the above addressed job site, employees were exposed to a fall hazard while installing metal wall studs from a fabricated frame scaffold that was not fully planked.    PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • · I (S) $2450
  • · Z (S) $4900

1926.451 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 18, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    a) On or about June 16, 2014, at the above addressed job site, employees were exposed to a fall hazard while installing metal wall studs from a fabricated frame scaffold that did not have base plates.    PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • · I (S) $2450
  • · Z (S) $4900

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 18, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces and end rails were used as a means of access:    a) On or about June 16, 2014, at the above addressed job site, employees were exposed to a fall hazard while performing masonry work on a fabricated frame scaffold which was not equipped with access ladders.    PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • · I (S) $2450
  • · Z (S) $4900

1926.451 F03

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 18, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    a)  On or about June 16, 2014, at the above addressed job site, employees were exposed to a fall hazard while installing metal wall studs from a deficient fabricated frame scaffold that lacked base plates, access ladders, and was not fully planked, had not been inspected by a competent person before each work shift.     PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • · I (S) $2450
  • · Z (S) $4900

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 18, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, or a personal fall arrest system:    a) On or about June 16, 2014, at the above addressed job site, employees were exposed to a fall hazard while installing metal wall studs on a roof without a means of conventional fall protection.    PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • · I (S) $2450
  • · Z (S) $4900

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 18, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    (a) On or about June 16, 2014, at the above addressed job site, employees were exposed to a fall hazard while installing metal wall studs and using a portable extension ladder that did not extend 3 feet above the upper landing.    PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.
Recent events (2)
  • · I (S) $2450
  • · Z (S) $4900

1926.1053 B04

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Nov 18, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    a) On or about June 16, 2014, at the above addressed job site, employees were exposed to a fall hazard while installing metal wall studs and using an A frame step ladder in the closed position to access a working surface.     PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED.