On , OSHA opened a planned safety inspection of RAFAEL GARCIA in LOT #152 CRESSWIND AT LAKE LANIER, GAINESVILLE, GA 30504 (NAICS 238130). OSHA activity number 339828899.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAFAEL GARCIA
- Site address
- LOT #152 CRESSWIND AT LAKE LANIER
- City
- GAINESVILLE
- State
- GA
- ZIP
- 30504
- Mailing
- 3842 ELMSIDE VILLAGE LANE APT A, NORCROSS, GA 30092
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 17, 2014
- Abate by
- Oct 14, 2014
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about June 12, 2014: a) Employees installing roof sheathing were exposed to fall hazards of approximately 12.6 feet to the inside of the structure, when they were not using any fall protection measures.
Recent events (1)
- — Z (S) $2400
1926.404 F06
- Issued
- Sep 17, 2014
- Abate by
- Oct 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: On or about June 12, 2014: a) Employee utilizing an reciprocating saw to make a cut to a top plate, was exposed to electrical shock when the flexible cord being used to power saw was missing the grounding pin.
Recent events (1)
- — Z (O) $0
1926.405 A02 II J
- Issued
- Sep 17, 2014
- Abate by
- Oct 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not of the three-wire type: On or about June 12, 2014: a) Employee utilizing a circular saw was exposed to electrical hazards when using a cord to power the saw was not of the three wire type.
Recent events (1)
- — Z (O) $0
More inspections at Rafael Garcia
View Rafael Garcia's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339828899.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.