POST FALLS, ID —
OSHA Inspection: SOLID ROCK GATE SUPPLY, INC DBA WELDING FABRICATION SERVICES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SOLID ROCK GATE SUPPLY, INC DBA WELDING FABRICATION SERVICES in 6955 N. PLEASANT VIEW RD., POST FALLS, ID 83854 (NAICS 332323). OSHA activity number 339831455.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 6955 N. PLEASANT VIEW RD.
- City
- POST FALLS
- State
- ID
- ZIP
- 83854
- Mailing
- 6955 N. PLEASANT VIEW RD., POST FALLS, ID 83854
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 23
- Ownership type
- A
Citations
17 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) On or about June 24, 2014, and at times prior thereto, the employer did not ensure and/or enforce the use of seat belts while operating powered industrial trucks. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.178 A04
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: (a) On or about June 24, 2014, and at times prior thereto, the employer drilled holes in the tynes of the forklifts. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Sep 30, 2014
- Abate by
- Dec 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) On or about June 24, 2014, and at times prior thereto, the employer authorized and/or directed employees to operate powered industrial trucks. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L03 I M
- Issued
- Sep 30, 2014
- Abate by
- Dec 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(3)(i)(M): Powered industrial truck operators did not receive initial training in the following topics to include but not limited to operating instructions, warnings, or precautions listed in the operators manual for the types of vehicle that the employee is being trained to operate: (a) On or about June 24, 2014, and at times prior thereto, the employer did not have the operators manual available for the powered industrial truck(s). Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.23 E04
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.23(e)(4): A standard toeboard was not provided with a 4 inches nominal in vertical height from its top edge to the level of the floor and securely fastened in place with not more than 1/4 inch clearance above the floor level. (a) On or about June 24, 2014 and at times prior thereto; Machine shop employees exposed to overhead hazards while employees utilized the upper mezzanine break/lunchroom. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.23 E06
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(6): Handrails and railings were not provided with a clearance of not less than 3 inches between the handrail or railing and any other object: (a) On or about June 24, 2014 and at times prior thereto, Upper mezzanine (break/lunch room), wire ropes were not taut and exposed employees to an approximate 8 foot 11 inch fall hazard Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 B05
- Issued
- Sep 30, 2014
- Abate by
- Dec 1, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.179(b)(5): The rated load of the crane was not plainly marked on each side of the crane. (a) Weld shop: On or about June 24, 2014, and at times prior thereto, Overhead jib crane. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.179 J02 III
- Issued
- Sep 30, 2014
- Abate by
- Dec 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed: (a) Weld shop: On or about June 24, 2014, and at times prior thereto, The employer did not implement inspection procedures for the hooks and/or chain hoists to assure that the equipment is in good operation condition and the hook on the jib crane was found defective with the latch missing. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J02 IV
- Issued
- Sep 30, 2014
- Abate by
- Dec 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed: (a) Weld shop: On or about June 24, 2014, and at times prior thereto, Overhead jib crane. (b) Machine shop: On or about June 24, 2014, and at times prior thereto, shop crane/hoist "cherry picker." Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J03
- Issued
- Sep 30, 2014
- Abate by
- Dec 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(3): The items listed in subparagraphs (j)(3)(i) -(j)(3)(x) were not inspected for defects at intervals as defined in paragraph(j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard. (a) Weld shop: On or about June 24, 2014, and at times prior thereto, Overhead jib crane. (b) Machine shop: On or about June 24, 2014, and at times prior thereto, shop crane/hoist "cherry picker." Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 L01
- Issued
- Sep 30, 2014
- Abate by
- Dec 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(l)(1): A preventive maintenance program based on the crane manufacturer's recommendations was not established: (a) Weld shop: On or about June 24, 2014, and at times prior thereto, Overhead jib crane. (b) Machine shop: On or about June 24, 2014, and at times prior thereto, shop crane/hoist "cherry picker." Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 D01
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. (a) On or about June 24, 2014, and at times prior thereto, the mezzanine utilized for breaks and/or lunch above the warehouse machinist shop. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: (a) On or about June 24, 2014, the employer did not initiate a monthly inspection requirement for the portable fire extinguishers in the workplace. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.215 B09
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: (a) On or about June 24, 2014, and at times prior thereto, a Clark, serial 84379 did not have a peripheral 'tongue' or 'chip' guard installed. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling. (a) On or about June 24, 2014, and at times prior thereto, a household outlet cover was utilized on Lathe #1. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 B02 III
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(2)(iii): The grounding contacts of receptacles and cord connectors were not grounded by connection to the equipment grounding conductor of the circuit supplying the receptacle or cord connector. (a) On or about June 24, 2014, and at times prior thereto, Lathe #1 The light on the electrical testing device remained "ON" when the "Test" button was pushed representing the fact that the GFCI was not working properly and/or had been incorrectly installed (miswired). Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) On or about June 24, 2014, and at times prior thereto, the lower junction box at the main breaker panel. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Solid Rock Gate Supply, INC DBA Welding Fabrication Services
View Solid Rock Gate Supply, INC DBA Welding Fabrication Services's full OSHA safety record →
More inspections in this industry (NAICS 332323)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339831455.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.