GREENVILLE, TX —
OSHA Inspection: KENT'S METAL CRAFT
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of KENT'S METAL CRAFT in 4702 LEE STREET, GREENVILLE, TX 75401 (NAICS 332322). OSHA activity number 339832586.
Where did this inspection happen?
- Establishment
- KENT'S METAL CRAFT
- Site address
- 4702 LEE STREET
- City
- GREENVILLE
- State
- TX
- ZIP
- 75401
- Mailing
- 4702 LEE STREET, GREENVILLE, TX 75401
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 8
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.107 B05 IV
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: This violation was discovered on or about July 1, 2014, in the paint booth, where space on the downstream and upstream sides of filters were not protected with approved automatic sprinklers.
Recent events (2)
- — I (S) $500
- — Z (S) $2000
1910.107 C05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(c)(5): Electrical equipment not approved for locations containing both deposits of readily ignitable residues and explosive vapors was present in spraying area(s): This violation was discovered on or about July 1, 2014, in the paint booth, where electrical equipment including, but not limited to, snap switches for an exhaust fan and lighting, were not approved for locations containing deposits of readily ignitable residues and explosive vapors.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 E02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 degrees F (93 degrees C) kept in the vicinity of spraying operations were not a minimum required for operations or they exceeded a supply for one day or one shift: This violation was discovered on or about July 1, 2014, in the paint booth, where flammable liquids including lacquer thinner and spray paints were stored in the paint booth.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: This violation was discovered on or about July 1, 2014, in the paint booth, where paint residue had accumulated on walls and on equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $650.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: This violation was discovered on or about October 2, 2014, when the employer had not established a program consisting of energy control procedures, employee training, and periodic inspections to ensure the control of hazardous energy during die changes on mechanical press brakes.
Recent events (2)
- — I (S) $650
- — Z (S) $2800
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $650.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): This violation was discovered on or about July 1, 2014, when employees operated a forklift without having first completed a training program consisting of formal instruction, practical training, and evaluation.
Recent events (2)
- — I (S) $650
- — Z (S) $2800
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $420.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): This violation was discovered on or about October 2, 2014, in the sheet metal shop, where employees were exposed to point of operation hazards while operating mechanical press brakes.
Recent events (2)
- — I (S) $420
- — Z (S) $2000
1910.243 C03
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel: This violation was discovered on or about July 1, 2014, in the fabrication and welding shops, where employees used portable grinders without guards.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $420.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: This violation was discovered on or about July 1, 2014, in the welding shop, where the outer insulation to a flexible cord supplying power to a 220-volt chop saw had separated from the fitting, exposing inner conductors to strain.
Recent events (2)
- — I (S) $420
- — Z (S) $1600
More inspections in this industry (NAICS 332322)
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
BRIDGEPORT, WV—2026-07-14
MID ATLANTIC METALWORKS INC.
KISSIMMEE, FL—2026-07-14
JELD-WEN
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339832586.