OSHA Inspection: LANDVATTER READY MIX, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LANDVATTER READY MIX, INC. in 3000 BARRETT STATION ROAD, KIRKWOOD, MO 63122 (NAICS 327320). OSHA activity number 339833972.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Landvatter Ready MIX, INC. for free Get an email when a new federal OSHA severe-injury report for Landvatter Ready MIX, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3000 BARRETT STATION ROAD
City
KIRKWOOD
State
MO
ZIP
63122
Mailing
3000 BARRETT STATION ROAD, KIRKWOOD, MO 63122
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
42
Ownership type
Private (A)

6 citations on file for this inspection.

1910.23 A08

Serious Gravity 1 1 instance 30 exposed
Issued
Oct 15, 2014
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons could accidentally walk was not guarded by either a standard railing with standard toe-board on all exposed sides, or a floor hole cover of standard strength and construction.  While the cover was not in place, the floor hole was not constantly attended by someone or protected by a removable standard railing:   Wash Rack area: A ground hole which measured 2 1/2 inches by 21 inches was not covered to prevent employee injuries.  Batch Operations area: A sump pump hole was left uncovered exposing employees to trip hazards.
Recent events (2)
  • · I (S) $1249.5
  • · Z (S) $1785

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 15, 2014
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   Shop: A Delta table drill press did not have a guard to prevent employee contact with rotating chuck and drill bit and a Makita cut-off saw had a non-functioning guard.
Recent events (2)
  • · I (S) $2082.5
  • · Z (S) $2975

1910.219 D01

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 15, 2014
Penalty
Initial $1,517 · Current $1,062 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):   Mechanic Shop: Pulleys which were approximately 64 inches from workplace floor were not guarded to prevent operator injuries.
Recent events (2)
  • · I (S) $1061.9
  • · Z (S) $1517

1910.219 E01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:   Mechanic Shop: Belt of a Delta drill press which was 64 inches from work place floor was not guarded to prevent employee injuries.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 15, 2014
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   Mechanic Shop:  Flexible cord connected to an outlet was used to supply power to a wall mounted quadruplet receptacle outlet box through a hole at the top of the wall mounted quadruplet outlet box.  Various pieces of electrical equipment were energized from the quadruplet receptacle outlet at different times.
Recent events (2)
  • · I (S) $2082.5
  • · Z (S) $2975

1910.305 G01 IV B

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 15, 2014
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:     Batch Room: Flexible cords and flexible cord sets used to energize various pieces of electrical equipment were run through holes in the ceiling.
Recent events (2)
  • · I (S) $2082.5
  • · Z (S) $2975

View Landvatter Ready MIX, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339833972.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.