FORT BELVOIR, VA ·
OSHA Inspection: LINEAL INDUSTRIES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LINEAL INDUSTRIES in 9910 TRACY LOOP, FORT BELVOIR, VA 22060 (NAICS 237130). OSHA activity number 339834483.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LINEAL INDUSTRIES
- Site address
- 9910 TRACY LOOP
- City
- FORT BELVOIR
- State
- VA
- ZIP
- 22060
- Mailing
- 1410 INGRAM AVE, RICHMOND, VA 23224
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 C02
- Issued
- Aug 12, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a.) Fort Belvoir Army Base: On or about 06/25/14, a means of emergency egress was not provided in that an employee was in a 7' trench without a ladder, thereby exposed employee to a potential cave-in. No abatement certification or documentation required.
Recent events (2)
- · I (S) $0
- · Z (S) $2800
1926.652 C02 I
- Issued
- Aug 12, 2014
- Abate by
- Sep 8, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data shall be in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer. a.) Fort Belvoir Army Base: On or about 06/25/14, the vertical aluminum hydraulic (Speed Shores) and fin-form boards used in a 7' trench were not installed according to the manufacturer's tabulated data for type "C" soil. Note: Speed shore maximum spacing every 4' in depth. The sheeting (fin-form) must extend to the bottom of the excavation. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $2800
- · Z (S) $2800
More inspections at Lineal Industries
View Lineal Industries's full OSHA safety record →
More inspections in this industry (NAICS 237130)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339834483.