Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: BRIGHT STAR HOMES, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRIGHT STAR HOMES, LLC. in 4020 CYBER AVENUE, COLUMBUS, OH 43213 (NAICS 238130). OSHA activity number 339835514.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bright Star Homes, LLC. for free Get an email when a new federal OSHA severe-injury report for Bright Star Homes, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
4020 CYBER AVENUE
City
COLUMBUS
State
OH
ZIP
43213
Mailing
2187 FERRIS ROAD, COLUMBUS, OH 43224
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
Private (A)

4 citations on file for this inspection.

1926.404 F06

Serious Gravity 1 1 instance 5 exposed
Issued
Jul 29, 2014
Abate by
Aug 16, 2014
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.  a. At the worksite where employees were using an extension cord to provide power to a circular saw, the ground prong was missing from the extension cord, thereby exposing employees to an electrical contact hazard.
Recent events (2)
  • · I (S) $510
  • · Z (S) $1020

1926.405 A02 II I

Serious Gravity 1 1 instance 5 exposed
Issued
Jul 29, 2014
Abate by
Aug 16, 2014
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage.  a. In between building 14 and 20 where employees laid an extension cord across a roadway, the extension cord was not protected from vehicular damage, thereby exposing employees to an electrical contact hazard.
Recent events (2)
  • · I (S) $510
  • · Z (S) $1020

1926.405 G02 IV

Serious Gravity 1 1 instance 5 exposed
Issued
Jul 29, 2014
Abate by
Aug 16, 2014
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  a. At the worksite where employees were using an extension cord to provide power to a circular saw, the strain relief of the male plug was pulled away from the outer insulating jacket of the extension cord, thereby exposing employees to an electrical contact hazard.
Recent events (2)
  • · I (S) $510
  • · Z (S) $1020

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 29, 2014
Abate by
Aug 16, 2014
Penalty
Initial $1,700 · Current $845 Reduced
29 CFR 1926.453(b)(2)(v): A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.  Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e).    a. At building 20 where an employee was working from the elevated basket of an aerial lift, a fall protection was not used, thereby exposing the employee to a 19 foot fall hazard.
Recent events (2)
  • · I (S) $845
  • · Z (S) $1700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339835514.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.