On , OSHA opened a programmed Related safety inspection of THE ROOFING GUYS in 3622 SOUTH EAST TOWNLINE ROAD, MARCELLUS, NY 13108 (NAICS 238160). OSHA activity number 339835779.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Roofing Guys for free Get an email when a new federal OSHA severe-injury report for The Roofing Guys is published. One employer, no account, unsubscribe in one click.
Establishment
THE ROOFING GUYS
Site address
3622 SOUTH EAST TOWNLINE ROAD
City
MARCELLUS
State
NY
ZIP
13108
Mailing
75 CHERRY TREE CIRCLE, LIVERPOOL, NY 13090
Inspection type
Programmed Related (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
12
Ownership type
Private (A)

6 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 3 exposed
Issued
Nov 13, 2015
Abate by
Dec 3, 2015
Penalty
Initial $440 · Current $0 Reduced
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:    a) At the jobsite, on or about 11/13/2015:  The employer did not provide abatement certification for Citation 01, Items 001, 002a, 002b, Citation 02, Items 001a and 001b issued on December 19, 2014.  An abatement demand letter was sent to the employer on October 23, 2015.      Abatement documentation is required for this item.
Recent events (2)
  • · I (O) $0
  • · Z (O) $440

1926.502 D06 III

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 19, 2014
Abate by
Dec 25, 2014
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1926.502(d)(6)(iii): A snaphook not of the locking type was engaged to a D-ring to which another snaphook or other connector is attached; such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself.    a)  At the jobsite, on the roof, on or about 7/2/14:  Employees were working on a 6:12 slope roof while using personal fall protection equipment where two connectors were attached to one anchor point d-ring creating the potential for side-loading and subsequent disengagement.        Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $1540
  • · C (S) $3080
  • · Z (S) $3080

1926.502 D16 III

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 19, 2014
Abate by
Dec 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    a)  At the jobsite, on the roof, on or about 7/2/14:  An employee was working on a 6:12 slope roof while using personal fall protection equipment where the location of the anchor point and the length of the lanyard ensured an 8 foot free-fall and contact with the side of the building in the event of a fall.    b)  At the jobsite, on the roof, on or about 7/2/14:  Employees were working on a 6:12 slope roof while using personal fall protection equipment where the location of the anchor point and the length of the lanyard would have ensured a greater than 6 foot free-fall and contact with the side of the building or with the ground (12 and 17 feet from ground).          Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1926.501 B13

Willful Gravity 10 1 instance 12 exposed
Issued
Dec 19, 2014
Abate by
Dec 25, 2014
Penalty
Initial $30,800 · Current $15,400 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system.    a)  At the jobsite, on the roof, on or about 7/2/14:  The employer does not require each employee working 6 feet or greater above a lower level to be protected from fall hazards by guardrails or personal fall protection systems.  This violation was most recently observed at the worksite located at 3622 South East Townline Road in Marcellus, NY where employees working on a 6:12 slope roof with approximate ground to eave heights of 12 and 17 feet without fall protection.  To abate this violation, the employer musts ensure that it's employees are protected from falls when working at 6 feet or greater above lower levels.      The Roofing Guys was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 942969, citation number 1, item number 1 and was affirmed as a final order on 3/13/14, with respect to a workplace located at 4436 Ashfield Terrace, Syracuse, NY.     The Roofing Guys was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 921490, citation number 2, item number 1, and was affirmed as a final order on 9/19/14, with respect to a workplace located at 129 Iron Oak Circle, North Syracuse, NY.      Note:  Pursuant to 29 CFR 1903.19, the employer must submit documents describing the steps it is taking to ensure compliance with the requirements set forth in 29 CFR 1926.501(b)(13), including a description of how these steps protect its employees from fall hazards.
Recent events (3)
  • · J (W) $15400
  • · C (W) $30800
  • · Z (W) $30800

1926.502 A02

Willful Gravity 10 4 instances 12 exposed
Issued
Dec 19, 2014
Abate by
Dec 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(a)(2): The employer did not provide and install all fall protection systems required by this subpart for employee(s) and did not comply with all other pertinent requirements of this subpart before employee(s) began the work that necessitates the fall protection.    a)  At the jobsite, on the roof, on or about 7/2/14:  The employer does not require each employee working 6 feet or greater above a lower level to be protected from fall hazards by guardrails or personal fall protection systems.  This violation was most recently observed at the worksite located at 3622 South East Townline Road in Marcellus, NY where employees working on a 6:12 slope roof with approximate ground to eave heights of 12 and 17 feet and with skylights approximately 10 feet to the lower level without fall protection.  To abate this violation, the employer musts ensure that it's employees are protected from falls when working at 6 feet or greater above lower levels.      b)  At the jobsite, on the roof, on or about 7/2/14:  The employer does not require each employee working 6 feet or greater above a lower level to be protected from fall hazards by guardrails or effective use of personal fall protection systems.  This violation was most recently observed at the worksite located at 3622 South East Townline Road in Marcellus, NY where employees working on a 6:12 slope roof with approximate ground to eave heights of 12 and 17 feet where two connections were made to a single D-ring anchor point.  To abate this violation, the employer musts ensure that it's employees are protected from falls when working at 6 feet or greater above lower levels.      c)  At the jobsite, on the roof, on or about 7/2/14:  The employer does not require each employee working 6 feet or greater above a lower level to be protected from fall hazards by guardrails or effective use of personal fall protection systems.  This violation was most recently observed at the worksite located at 3622 South East Townline Road in Marcellus, NY where an employee was connected to an anchor point where the location of that anchor and the length of the lanyard ensured an 8 foot free-fall and contact with the side of the building in the event of a fall.  To abate this violation, the employer musts ensure that it's employees are protected from falls when working at 6 feet or greater above lower levels.      d)  At the jobsite, on the roof, on or about 7/2/14: The employer does not require each employee working 6 feet or greater above a lower level to be protected from fall hazards by guardrails or effective use of personal fall protection systems.  This violation was most recently observed at the worksite located at 3622 South East Townline Road in Marcellus, NY where the location of the anchor point and the length of the lanyard would have ensured a greater than 6 foot free-fall and contact with the side of the building or with the ground.  To abate this violation, the employer musts ensure that it's employees are protected from falls when working at 6 feet or greater above lower levels.      The Roofing Guys was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 942969, citation number 1, item number 1 and was affirmed as a final order on 3/13/14, with respect to a workplace located at 4436 Ashfield Terrace, Syracuse, NY.     The Roofing Guys was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 921490, citation number 2, item number 1, and was affirmed as a final order on 9/19/14, with respect to a workplace located at 129 Iron Oak Circle, North Syracuse, NY.      Note:  Pursuant to 29 CFR 1903.19, the employer must submit documents describing the steps it is taking to ensure compliance with the requirements set forth in 29 CFR 1926.502(a)(2), including a description of how these steps protect its employees from fall hazards.
Recent events (3)
  • · J (W) $0
  • · C (W) $0
  • · Z (W) $0

1926.501 B13

Serious Gravity 5 1 instance 12 exposed
Issued
Dec 19, 2014
Abate by
Dec 25, 2014
Penalty
Initial $2,200 · Current $0 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a)  At the jobsite, on the roof, on or about 7/2/14:  Employees were working on 6:12 slope roof without fall protection where skylights were present and workers were not protected from falling through to the lower level approximately 10 feet.      Abatement certification must be submitted for this item.
Recent events (3)
  • · J (S) $0
  • · C (S) $2200
  • · Z (S) $2200